!WARNING: If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully followed.

Insulation Blankets

Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary.

The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property.

The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices.

!CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater:

Do not cover the temperature and pressure relief valve.

Do not cover jacket access panels to thermostats and heating elements.

Do not cover the electrical junction box of the water heater.

Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket.

Safety Instructions Installation Instructions Operating Instructions

Hot and Cold Pipe Insulation Installation

H

 

 

 

 

OT

 

L E

R

 

 

E I

 

 

F

 

 

V

 

 

EV

L A

 

 

 

 

CO

 

 

 

 

LD

H

 

 

 

 

 

OT

 

 

ER

 

 

 

IL

 

F

E

 

 

 

 

 

 

L A

V

 

 

EV

 

 

 

 

 

 

 

 

 

CO

 

 

 

 

 

LD

Typical vertical piping

Typical horizontal piping

Typical side piping

arrangement

 

arrangement

arrangement

For increased energy efficiency, some

Please install the insulation, according to

water heaters have been supplied with

the illustrations above, that best meets

two 24” sections of pipe insulation.

your requirements.

 

Care and Cleaning Troubleshooting Tips Customer Service

9

Page 9
Image 9
GE AP12170-4 Insulation Blankets, Hot and Cold Pipe Insulation Installation, Illustrations above, that best meets

GE30T06MAG, AP12170-4 specifications

The GE AP12170-4, also known as the GE30T06MAG, is a cutting-edge product designed to enhance efficiency and reliability in various industrial applications. This model has garnered attention due to its advanced features, robust technologies, and overall performance characteristics.

One of the standout features of the GE AP12170-4 is its high power capacity, which enables it to handle demanding loads in large industrial environments. The device is engineered to maintain continuous operation even under extreme conditions, making it ideal for critical infrastructures where downtime is not an option. Its durable construction is designed to withstand harsh environmental factors, ensuring longevity and consistent performance.

In terms of technology, the GE AP12170-4 integrates state-of-the-art control systems that facilitate precise monitoring and management of electrical loads. This technology allows users to optimize energy consumption while simultaneously safeguarding against overloads. The built-in diagnostics and data logging capabilities provide real-time insights into operational efficiency and can be crucial for predictive maintenance, reducing unexpected failures and operational costs.

Additionally, this model features advanced safety mechanisms, including surge protection and fault detection systems, which are essential for minimizing risks associated with electrical surges and other anomalies. This focus on safety extends to user-friendly interfaces, which simplify the operation and maintenance of the device. Operators can easily navigate through settings and troubleshoot potential issues, enhancing overall usability.

The GE AP12170-4 also incorporates flexible connectivity options, allowing it to integrate seamlessly into existing systems. Whether using legacy communication protocols or modern networks, users can enjoy versatile connectivity that enhances interoperability with other industrial equipment. This adaptability is vital for facilities undergoing digital transformation and seeking to improve operational efficiency.

Moreover, the design of the GE AP12170-4 emphasizes energy efficiency, contributing to lower operational costs and reduced environmental impact. By optimizing performance and reducing energy waste, it aligns with the growing demand for sustainable practices in industrial operations.

Overall, the GE AP12170-4, or GE30T06MAG, represents a blend of power, reliability, and advanced technology. Its comprehensive features equip industries to meet the challenges of modern operations while prioritizing safety, efficiency, and sustainability. Whether in manufacturing, utility, or larger infrastructure projects, this model stands out as a versatile solution for meeting the demands of today’s industrial landscape.