Set Regeneration (Starting) Time

NOTE: RECHARGE TIME and a flashing 2:00 AM (factory default) should show in the display. This is a good time for regeneration to start (over in about 2 hours) in most households because water is not in use. HARD WATER is bypassed to house faucets during regeneration. See the Automatic Hard Water Bypass During Regeneration section.

1 Press the UP or DOWN button to set the desired regeneration start time.

NOTE: Each press of the buttons changes the time by one hour. Holding the buttons in changes the time twice each second.

Be sure to observe the AM or PM as you did when setting the time of day.

2 Press the SELECT button once more.

The display shows the present time of day and

RECHARGE TONIGHT .

Safety Instructions

Normal Operation, Control Displays

During normal operation, the present time of day and AM or PM show in the control display area. When the demand computer determines a regeneration is needed, RECHARGE TONIGHT begins to flash in the

display along with the present time. RECHARGE TONIGHT flashes until the next regeneration start time, then changes to RECHARGE NOW, which flashes until the regeneration is over.

Operating

Feature: Optional Recharge Controls

Sometimes, a manually started regeneration (recharge) may be desired or needed. Two

examples:

You have used more water than usual (house guests, extra washing, etc.) and you may run out of soft water before the next regeneration.

You did not refill the storage tank with salt.

Use one of the following features to start a regeneration immediately, or at the next preset regeneration start time.

RECHARGE TONIGHT

Touch (do not hold) the TOUCH or HOLD button. RECHARGE TONIGHT flashes in the control display area. A regeneration will occur at the next preset regeneration start time. If you decide to cancel this regeneration, touch the same button once more.

RECHARGE NOW

Press and hold the TOUCH or HOLD button until RECHARGE NOW starts to flash in the control display area. The water softening system begins an immediate regeneration and, when over in about two hours, you will have a new supply of soft water. Once started, you cannot cancel this regeneration.

Instructions

Troubleshooting

Feature: Program Memory

If electrical power to the water softening system is interrupted, the control display is blank, but the control keeps correct time for about six hours.

When power is restored, you have to reset the present time only if the display is flashing. All other settings are maintained and never require resetting unless a change is desired.

If the time is flashing after a long power outage, the water softening system continues to work as it should to provide you with soft water. However, regenerations may occur at the wrong time of day until you reset the control to the correct time of day.

Tips

Feature/Service: Automatic Electronic Diagnostics

Customer

The control computer has a self-diagnostic function for the electrical system (except input power and water meter). The computer monitors the electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the control display.

The chart on Error Codes shows the error codes that could appear and possible reasons for each code. While an error code is displayed, all control buttons are inoperable except for the SELECT button. SELECT remains operational so the service person can make the Manually Initiated Electronic Diagnostics to further isolate the defect and check the water meter.

Service

7

Page 7
Image 7
GE GNSF18Z01 Set Regeneration Starting Time, Normal Operation, Control Displays, Feature Optional Recharge Controls

GNSF23Z01, GNSF18Z01, GNSF35Z01 specifications

The GE GNSF series, which includes models GNSF18Z01, GNSF35Z01, and GNSF23Z01, represents a significant stride in the realm of energy-efficient heating and cooling solutions. These heat pump systems are designed to cater to both residential and commercial applications, making them versatile options in a range of settings.

The GNSF18Z01 model is a compact yet powerful option, featuring a 1.5-ton cooling capacity with a SEER rating of up to 18, ensuring excellent energy efficiency. This model utilizes a scroll compressor, known for its durability and quiet operation. Its environmentally friendly refrigerant, R-410A, helps reduce greenhouse gas emissions while delivering optimal cooling performance. Moreover, the easy-to-use programmable thermostat enhances user control over energy consumption, allowing homeowners to manage their comfort levels more effectively.

Similarly, the GNSF23Z01 model stands out with its 2-ton capacity, featuring a slightly higher SEER rating. This model is ideal for larger spaces that require robust cooling and heating support. The technology embedded in the GNSF23Z01 also includes variable speed operation, which adjusts to the cooling demand in real-time, providing significant energy savings. The model’s advanced air filtration system contributes to improved indoor air quality by capturing dust, allergens, and other particulate matter.

The GNSF35Z01 model offers even greater efficiency with its 3-ton cooling capacity and an impressive SEER rating that surpasses many competitors in the marketplace. This heat pump incorporates advanced smart technology, allowing integration with home automation systems. Users can easily monitor and adjust settings remotely through mobile applications, providing unparalleled convenience. The GNSF35Z01 also emphasizes sustainability with its energy-saving features, aligning with modern eco-friendly practices.

In addition to energy efficiency, all three models share a focus on quiet operation, streamlined design, and ease of installation, making them suitable for various building structures. Their robust construction ensures longevity and reliability, contributing to lower maintenance costs over their lifespan. Overall, the GE GNSF18Z01, GNSF35Z01, and GNSF23Z01 heat pumps are exemplary choices for anyone seeking efficiency, comfort, and advanced technology in their heating and cooling systems.