PLANNING FOR PLUMBING

Installation Instructions

PLANNING FOR PLUMBING

(shown with optional pipe cover)

Unit

18″ min.

612

 

7″

 

 

12″

412

 

978

 

Water and gas

338

through the wall *

 

9″

36Manual background″ min.

Optional Pipe Cover (AGTPCM)Manual background shown shaded.Manual backgroundManual background

Pipe cover not required, However, consideration should be taken in the design of the rough plumbing to allow installation of unit and pipe cover

212

Manual backgroundManual background 212Manual background

Manual background 212Manual background

Ground

*Suggested area for Water and Gas lines to come through the wall to allow the optional pipe cover to be installed if desired.

The center of the pipes can be placed anywhere within the shaded area. The center of the pipes is recommended to be protruding only within 6″ of the mounting wall. Other specific installations may be different.

Be sure that the minimum elevation of the bottom of the unit is 18″ to meet the 36″ recommended clearance for the exhaust.

CAUTION: BURN HAZARD. Hot exhaust and vent may cause serious burns. Keep back from water heater unit. Keep small children and animals away from unit.

CAUTION: Hot Water outlet pipes leaving unit can be hot to touch. Insulation must be used for hot water pipes below 36″ due to burn risk to children.

NOTE: It is recommended to install the bottom

of the unit at least 18″ off the ground to minimize blockage and maintenance from debris and provide room for the optional Pipe Cover Accessory Model Number AGTPCM.

NOTE: Do not install electrical outlet directly below unit. Electrical outlet must be installed less than 6 feet from unit.