Installation Instructions

1INSTALLING THE WATER LINE (CONT.)

,QVWDOOWKHVKXWRȺYDOYHRQWKHQHDUHVWIUHTXHQWO\XVHGGULQNLQJZDWHUOLQH

1SHUT OFF THE MAIN WATER SUPPLY AND UNPLUG REFRIGERATOR

Turn on the nearest faucet (counterclockwise) long enough to clear the line of water.

2 CHOOSE THE VALVE LOCATION

Choose a location for the valve that is easily accessible. It is best to connect into the side

of a vertical water pipe. When it is necessary to connect into a horizontal

water pipe, make the connection to the top or side, rather than at the bottom,

WRDYRLGGUDZLQJRȺDQ\VHGLPHQWIURP the water pipe.

3DRILL THE HOLE FOR THE VALVE

Drill a 1/4hole in the water pipe (even if using a self- piercing valve), using a sharp bit. Remove any burrs resulting from drilling the hole in the pipe. Take care not to allow water to drain into the drill. Failure to drill a 1/4hole may result in reduced ice production or smaller cubes.

5ROUTE THE TUBING

Route the tubing between the cold water line and the refrigerator.

Route the tubing through a hole drilled in the wall or

ÀRRU EHKLQGWKHUHIULJHUDWRURUDGMDFHQWEDVHFDELQHW  as close to the wall as possible.

NOTE:%HVXUHWKHUHLVVXȻFLHQWH[WUDWXELQJ DERXW feet [1.82 m] coiled into 2 turns of about 10[25 cm] diameter) to allow the refrigerator to move out from the wall after installation.

6CONNECT THE TUBING TO THE VALVE

Place the compression nut and ferrule (sleeve) for copper tubing onto the end of the tubing and connect

LWWRWKHVKXWRȺYDOYH

Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely.

For plastic tubing from a GE SmartConnectRefrigerator Tubing kit, insert the molded end of the

WXELQJLQWRWKHVKXWRȺYDOYHDQGWLJKWHQFRPSUHVVLRQ nut until it is hand tight, then tighten one additional turn with a wrench. Overtightening may cause leaks.

4 FASTEN THE SHUTOFF VALVE

Saddle-Type 6KXWRȺ9DOYH

Packing Nut

Outlet Valve

Compression

Nut

SmartConnect

Tubing

Ferrule (sleeve)

 )DVWHQWKHVKXWRȺYDOYHWRWKHFROGZDWHUSLSHZLWK

the pipe clamp.

Tighten the clamp screws until the sealing washer begins to swell.

NOTE: Do not overtighten or you may crush the

tubing.

Washer

Pipe Clamp

Inlet End

Clamp

Screw

Saddle-Type

6KXWRȺ9DOYHVertical Cold

Water Pipe

NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber.

NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber.

7FLUSH OUT THE TUBING

Turn the main water supply on

FRXQWHUFORFNZLVH DQGÀXVKRXWWKH tubing until the water is clear.

6KXWWKHZDWHURȺDWWKHZDWHUYDOYH after about one quart (1 liter) of water

KDVEHHQÀXVKHGWKURXJKWKHWXELQJ

9

Page 9
Image 9
GE GTE18GTHWW Choose the Valve Location, Drill the Hole for the Valve, Route the Tubing, Connect the Tubing to the Valve