Installation Instructions
REVERSE OSMOSIS SYSTEM ASSEMBLY AND STORAGE TANK INSTALLATION1Hold the Reverse Osmosis assembly up
to the wall surface where you will install it. Mark locations for the screws. The arrows on the top of the bracket show the location of the screw holes.
2Wood screws are included for fastening to a wood surface. Provide other screws as needed.
3Hang the Reverse Osmosis assembly on the screws.
4Apply pipe thread sealing tape to the tank fitting. Insert into tank threads. Tighten with a wrench.
5Connect the tubing to the storage tank: Run the length of 3/8″ orange tubing from the tee fitting on the Reverse Osmosis module to the tank inlet fitting.
To faucet
Supply line
Storage
tank
Orange tubing
2″ minimum clearance for changing cartridges
NOW THAT YOUR REVERSE OSMOSIS SYSTEM IS INSTALLED…SANITIZE!
Sanitize upon installation and after servicing inner parts, including replacement of prefilter, postfilter and the Reverse Osmosis cartridge. It is important to wash hands with
CAUTION: If installing unit in new construction, ensure that house plumbing is flushed thoroughly before opening the water supply valve. Also, before sanitizing, be sure to remove all cartridges as described in the Sanitization section. Chlorine will destroy the Reverse Osmosis cartridge.