POSSIBLE DEFECT

About the water softener system.

Service: Electronic Demand Time Features and Service

ERROR CODE DISPLAYED

ERR 01

ERR 02

ERR 03

ERR 04

ERR 05

 

 

 

 

 

 

POSSIBLE DEFECT

• Motor

• Position

• Motor

• Position

• Control

 

inoperative

switch

inoperative

switch or

 

 

 

 

or wiring

wiring

 

 

 

 

harness

harness

 

 

• Wiring harness

• Control

• Control

• Control

 

 

or connection

 

 

 

 

 

to switch

 

 

 

 

 

• Position switch

 

 

 

 

 

• Control

 

 

 

 

 

 

 

 

 

 

To remove an error code: 1. Unplug transformer.

2.Correct defect.

3.Plug transformer in.

4.Wait for at least 6 minutes. The error code will return if the reason for the error code was not corrected.

Service: Timer/Softener, Service Checkout Procedure

If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.

VISUAL CHECKS:

1.Is there electrical power to the outlet the water softening system transformer is plugged into?

2.Is there sufficient salt in the storage tank?

3.Is the softener bypass valve directing water for soft water service?

4.Is the valve drain hose open to the drain, not more than 8′ above the softener, and unobstructed? If hose is above 8′, see page 6, section 4.

If you do not find a problem with the visual checks, continue below.

NO SOFT

WATER

CONTROL SHOWS WRONG TIME AND DAY, AND/OR IS FLASHING.

Electrical power was off. Reset the correct time of day.

Investigate reason for power loss.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check electrical

 

 

 

 

 

CONTROL

 

 

 

power to control

 

 

 

 

 

DISPLAY

 

 

 

(outlet, transformer,

 

 

 

 

 

BLANK.

 

 

 

power cable, all

 

 

 

 

 

 

 

 

 

connections).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL DISPLAY SHOWS

 

 

 

 

 

 

 

 

 

 

Do manual

 

CORRECT TIME AND DAY

 

 

 

 

 

 

 

 

AND IS STEADY.

 

 

 

 

 

 

 

diagnostics.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO POWER To remove an error code: 1. Unplug transformer.VISUAL CHECKS: POWER OK NO SOFTManual background

REPAIR AS NEEDED

CONTROL DEFECTIVE

Do manual diagnostics to verify proper function.

14

Page 14
Image 14
GE GXSF27E About the water softener system, No Soft Water, Possible Defect, To remove an error code 1. Unplug transformer