GEAppliances.com
Service: Manually Initiated Electronics Diagnostics
1.To enter diagnostics, press and hold the MODE button until (000 –
A The first 3 digits indicate water meter operation as follows:
■000 (steady) = soft water not in use…no flow through the meter.
Turbine Switches
OR
Water | Switch (B) |
Meter (A) |
|
C While in this diagnostic screen, the following information |
is available and may be beneficial for various reasons. |
This information is retained by the computer from the |
first time electrical power is applied to the control. |
■ Press and hold the UP button to display the number |
of days this control has had electrical power applied. |
■ Press and hold the DOWN button to display the |
number of regenerations initiated by this control |
—OPEN A NEARBY SOFT WATER FAUCET—
■000 to 199 (continual) = repeats display for each gallon of water passing through the meter.
Motor
Position
switch
Sensor
housing Turbine
Valve | Turbine support |
and shaft | |
outlet |
|
If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.
BThe letter (P) and dash(es) indicate POSITION switch operation. The letter appearing means the switch is closed; the dash means the switch is open. Use the
RECHARGE (RECHARGE
CORRECT SWITCH |
|
DISPLAYS | VALVE CYCLE STATUS |
—— Valve in service, fill, brining, backwash or fast rinse position.
— P | Valve rotating from one position to another |
since the SR code number was entered. |
2. Press the MODE button and hold in three |
seconds until a Service Rating code appears in the display.
For correct water softening system
operation, the model code must be SR22 for model GXSF27E.
To reset the code, press the UP or DOWN button until the correct number shows.
3.Press the MODE button to return to the present time display.
If the code was changed, make ALL the timer settings.
NOTE: If the control is left in a diagnostic display or a flashing display when setting times or hardness, present time automatically returns if a button is not pressed within four minutes.
15