Installation Instructions

WARNING!

INSTALLATION SAFETY INSTRUCTIONS

Read these instructions completely and carefully.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

For assistance or additional information, consult a qualified installer, service agency, manufacturer (dealer) or the gas supplier.

Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use NEW flexible connectors when installing a gas appliance.

IMPORTANT Remove all packing material and literature from oven before connecting gas and electrical supply to range.

CAUTION Do not attempt to operate the oven of this range during a power failure (Electric Ignition models only).

Have your range installed by a qualified installer.

Your range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section.

Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring.

Do not install the range over carpeting unless a sheet of 1/4thick plywood or similar insulator is placed between the range and carpeting.

Make sure the wall coverings around the range can withstand heat generated by the range up to 200°F.

Avoid placing cabinets above the range. To reduce the hazard caused by reaching over the open flames of operating burners,

install a ventilation hood over the range that projects forward at least 5beyond the front of the cabinets.

The ventilating hood must be constructed of sheet metal not less than 0.0122thick.

Install above the cooktop with a clearance of not less than 1/4between the hood and the underside of the combustible material or metal cabinet. The hood must be at least as wide as the appliance and centered over the appliance. Clearance between the cooking surface and the ventilation hood surface MUST NEVER BE LESS THAN

24 INCHES.

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

If cabinets are placed above the range, allow a minimum clearance of 30between the cooking surface and the bottom of unprotected cabinets.

If a 30clearance between cooking surface and overhead combustible material or metal cabinets cannot be maintained, protect the

underside of the cabinets above the cooktop with not less than 1/4insulating millboard

covered with sheet metal not less than 0.0122thick. Clearance between the cooking surface and protected cabinets

MUST NEVER BE LESS THAN 24 INCHES.

The vertical distance from the plane of the cooking surface to the bottom of adjacent

overhead cabinets extending closer than

1to the plane of the range sides must not be less than 18. (See the Dimensions and Clearances illustration in this section.)

CAUTION Items of interest to children should not be stored in cabinets above a range or on the backsplash of a range—children climbing on the range to reach items could be seriously injured.

24

Page 24
Image 24
GE JGAS02 owner manual Installation Safety Instructions

JGAS02 specifications

The GE JGAS02 is an advanced gas turbine designed to meet the growing demand for efficient and reliable energy solutions. With a focus on performance and sustainability, the JGAS02 incorporates a series of cutting-edge technologies that enhance its operational capabilities while reducing its environmental footprint.

One of the standout features of the JGAS02 is its high efficiency rating. The turbine boasts an advanced airfoil design that optimizes airflow and enhances combustion efficiency. This results in reduced fuel consumption and lower emissions, making it an ideal choice for power generation in a world increasingly focused on clean energy solutions.

The JGAS02 utilizes a sophisticated control system that allows for precise monitoring and management of its operation. This system is equipped with predictive analytics, enabling operators to anticipate maintenance needs and minimize downtime. This not only increases the reliability of the turbine but also extends its operational lifespan, providing significant cost savings over time.

Another key characteristic of the JGAS02 is its versatility. It can operate with a variety of fuels, including natural gas, biogas, and even liquid fuels, allowing it to adapt to different market needs and regulatory environments. This flexibility makes it a popular choice for both industrial applications and power plants seeking to diversify their energy sources.

In terms of technology, the JGAS02 features state-of-the-art cooling systems that enhance turbine performance while protecting critical components from high temperatures. Proprietary materials and coatings are employed to ensure durability and longevity in demanding operating conditions.

Moreover, the JGAS02's modular design simplifies maintenance and upgrades, making it easier for operators to implement enhancements as technology evolves. This attention to future-proofing aligns with GE’s commitment to providing long-term value to its customers.

Overall, the GE JGAS02 represents a significant advancement in gas turbine technology. With its blend of high efficiency, operational reliability, and environmental sustainability, it is well-positioned to meet the challenges of modern energy production while supporting a transition to a cleaner energy future.