Installation Instructions

12INSTALL THE ANTI-TIP DEVICE (cont.)

DFor wood construction, drill a pilot hole at an angle of 20° from the horizontal.

A nail or awl may be used if a drill is not available.

Mount the Anti-Tip device with the screw provided.

For cement or concrete construction, you will need a 1/4x 112lag bolt and a 1/2O.D. sleeve anchor, which are not provided. Drill the recommended size hole for the hardware.

Wallboard

Back of

 

range

Anti-Tip

 

device

 

Wood screw

 

Install the sleeve anchor into the drilled hole and then install the lag bolt through the device. The bolts must be properly tightened as recommended for the hardware.

ESlide the range against the wall, and check for proper installation by grasping the front edge of the cooktop and carefully attempting to tilt the range forward.

WHEN ALL HOOKUPS ARE COMPLETED

Make sure all controls are left in the OFF position. Make sure the flow of combustion and ventilation air to the range is unobstructed.

Mobile Home Installation:

Be sure the installation of this range in a manufactured or mobile home conforms with the Manufactured Home Construction and Safety Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety Title 24, H.U.D.

(Part 280)] or when such standards are not applicable, the Standard for Manufactured Home Installations 1984 (Manufactured Home Sites Communities and Set-Ups), ANSI A225.1-latest edition, or with local codes. In Canada, mobile home installation must be in accordance with the current CAN/CSA Z240/MH Mobile Home Installation Code.

Model and Serial Number Location:

The serial plate for your range is located under the cooktop. See the Lift-Up Cooktop section in this manual for instructions on how to lift the cooktop. See the Lift-Up Cooktop section in this manual for instructions on how to lift the cooktop. In addition to the model and serial numbers, it tells you the ratings of the burners and type of fuel and pressure for which the range was adjusted when it left the factory.

When ordering parts, always include the model number and serial number to ensure proper replacement parts. Parts may be obtained through General Electric/Hotpoint Factory Service Centers or General Electric/Hotpoint authorized Customer Care® servicers.

CONVERT TO LP GAS (or convert back to natural gas from LP)

This range leaves the factory set for use with natural gas. If you want to convert to LP gas, the conversion must be performed by a qualified LP gas installer.

The conversion instructions and LP orifices can be found attached to the back of the range.

Keep these instructions and the orifices in case you want to convert back to natural gas.

33

Page 33
Image 33
GE JGAS02 owner manual When ALL Hookups are Completed, Mobile Home Installation, Model and Serial Number Location

JGAS02 specifications

The GE JGAS02 is an advanced gas turbine designed to meet the growing demand for efficient and reliable energy solutions. With a focus on performance and sustainability, the JGAS02 incorporates a series of cutting-edge technologies that enhance its operational capabilities while reducing its environmental footprint.

One of the standout features of the JGAS02 is its high efficiency rating. The turbine boasts an advanced airfoil design that optimizes airflow and enhances combustion efficiency. This results in reduced fuel consumption and lower emissions, making it an ideal choice for power generation in a world increasingly focused on clean energy solutions.

The JGAS02 utilizes a sophisticated control system that allows for precise monitoring and management of its operation. This system is equipped with predictive analytics, enabling operators to anticipate maintenance needs and minimize downtime. This not only increases the reliability of the turbine but also extends its operational lifespan, providing significant cost savings over time.

Another key characteristic of the JGAS02 is its versatility. It can operate with a variety of fuels, including natural gas, biogas, and even liquid fuels, allowing it to adapt to different market needs and regulatory environments. This flexibility makes it a popular choice for both industrial applications and power plants seeking to diversify their energy sources.

In terms of technology, the JGAS02 features state-of-the-art cooling systems that enhance turbine performance while protecting critical components from high temperatures. Proprietary materials and coatings are employed to ensure durability and longevity in demanding operating conditions.

Moreover, the JGAS02's modular design simplifies maintenance and upgrades, making it easier for operators to implement enhancements as technology evolves. This attention to future-proofing aligns with GE’s commitment to providing long-term value to its customers.

Overall, the GE JGAS02 represents a significant advancement in gas turbine technology. With its blend of high efficiency, operational reliability, and environmental sustainability, it is well-positioned to meet the challenges of modern energy production while supporting a transition to a cleaner energy future.