Installation Instructions

3ELECTRICAL CoNNECTIoNS (CoNT.)

B.Usage Situations where Appliance Power Cord will Be Disconnected Frequently.

Do not use an adapter plug in these situations because disconnecting of the power cord places undue strain on the adapter and leads to eventual failure of the adapter ground terminal. The customer should have the 2-prong wall receptacle replaced with a 3-prong (grounding) receptacle by a qualified electrician before using the appliance.

The installation of appliances designed for mobile home installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or, when such standard is not applicable, the Standard

for Manufactured Home Installations, latest edition (Manufactured Home Sites, Communities and Set-Ups), ANSI A225.1, latest edition, or with local codes. In Canada, mobile home installation must be in accordance with the current CAN/CSA Z240/MH Mobile Home Installation Code.

Electric Disconnect

nLocate disconnect plug on the range back.

nPinch sides of connector and pull out of range back.

5CHECK oPERATIoN oF SURFACE BURNERS

Operation of all cooktop and oven burners should be checked after the range and gas supply lines have been carefully checked for leaks.

Lighting the Burners

Select a top burner knob and simultaneously push in and turn to LITE position. You will hear a clicking sound indicating proper operation of the spark module. Once the air has been purged from the supply lines, burners should light within 4 seconds. After burner lights, rotate knob out of the LITE position. Try each burner in succession until all burners have been checked.

quality of Flames

The combustion quality of burner flames needs to be determined visually.

(A) Yellow flames—

Call for service

(B) Yellow tips on outer cones—

Normal for LP gas

(C) Soft blue flames—Normal for natural gas

If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use.

With LP gas, some yellow tipping on outer cones is normal.

4SEAL THE oPENINGS

Seal any openings in the wall behind the range and

in the floor under the range when hookups are completed.

42

6CHECK oPERATIoN oF oVEN BURNERS

A.Remove oven bottom:

nRemove the 2 screws at the rear of the oven bottom.

nGrasp the oven bottom at slots on each side.

nLift the rear enough to clear the lip of the range frame, push it back, and then pull it up and out.

Oven bottom