1 PROVIDE ADEQUATE GAS SUPPLY
Your range is designed to operate at a pressure of
25.4 cm (10″) of water column on butane gas. |
Gas Pipe and Electric Outlet Locations for Models Equipped with Sealed Burners
Make sure you are supplying your range with the |
type of gas for which it is designed. |
If you decide to use this range on a different type
This area allows for flush range installation with
76.2cm (30″)
of gas, conversion adjustments must be made by a service technician or other qualified person before attempting to operate the range on that gas.
For proper operation, the pressure of butane gas supplied to the regulator must be between 25.4 cm (10″) and 33 cm (13″) of water column. When checking for proper operation of the regulator, the inlet pressure must be at least 2.5 cm (1″) greater than the operating (manifold) pressure as given above. The pressure regulator located at the inlet of the range manifold must remain in the supply line. A flexible metal appliance connector used to
connection of pipe
Shortest connection from hard pipe
stub location to 10.2 cm range hookup.
(4″)
(10.2 cm) (4″)
20.3 cm (8″)
6.4cm (21⁄2″)
61cm (24″)
5.1 cm (2″)
connect the range to the gas supply line should have an I.D. of 1.3 cm (1/2″) and be 1.5 m (5′) in length for ease of installation. In Canada, flexible
22.9 cm (9″) | 15.9 cm | |
|
| (61⁄4″) |
|
|
C
L
connectors must be single wall metal connectors no longer than 1.8 m (6′) in length.
2 CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before disconnecting the old range and leave it off until
This area allows for flush range installation with
Gas Pipe and Electric Outlet Locations for Models Equipped with Standard Twin Burners
new
Because hard piping restricts movement of the range, the use of an
To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.
*Teflon: Registered trademark of DuPont
This area allows for flush range installation with
through-the-wall
connection of pipe
22.9 cm (9″)
76.2 cm | Shortest | |
connection | ||
(30″) | ||
from hard pipe | ||
| stub location to | |
17.8 cm | range hookup. |
10.2cm (7″)
(4″)
20.3 cm (8″)
73.7 cm (29″)
61 cm (24″)
5.1 cm (2″)
6.4 cm (21⁄2″)
C
L
This area allows for flush range installation with