CONTROL KNOBS

CONTROL KNOBS

Radiant Surface Unit

The control for the radiant surface

 

OFF

unit can be set anywhere between LO

LO

HI

 

 

and HI for an unlimited number of

 

 

heat settings.With the infinite switch

 

 

the coil cycles on and off to maintain

 

 

your selected control setting.

 

MED

The control knob must be pushed in and turned from the OFF position. When the control knobs are in any position other than off, they may be turned without pushing down.

Be sure you turn the control knob off when you finish cooking. You will feel a “click” at the OFF position. Cooktop temperatures increase with the number of surface units that are on. With 3 or 4 units turned on, surface temperatures are high so be careful when touching the cooktop. The HOT SURFACE lights will remain lit after the surface unit is off until the surface is cool enough to touch.

Settings:

HI—Quick start for cooking; brings water to a boil.

Medium High—(Setting halfway between HI and MED) Fast fry, pan broil; maintains a fast boil on large amounts of food.

MED—Sauté and brown; maintains a slow boil on large amounts of food.

Medium Low—(Setting halfway between MED and LO) Cook after starting at HI; cooks with little water in covered pan.

LO—Steam rice, cereal; maintains serving temperature of most foods. Slow cooking and simmering.

CAUTION: When the surface controls are turned off, the HOT SURFACE indicator light will remain lit until the cooktop surface has cooled to approximately 150°F. The glass ceramic surface will retain heat after the indicator light goes out. Use caution until the cooktop surface has had time to cool.

Radiant Dual Surface Unit and Control Knob

The right front radiant surface unit has 2 cooking sizes to select from so you can match the size of the unit to the size of the cookware you are using.

To use the large (9 inch) surface unit, turn the COIL SELECT knob clockwise to the position marked Radiant Surface Unit . Push in and turn the control knob to the desired setting. The unit will heat the entire area contained by the larger circle.

To use the small (6 inch) surface unit, turn the COIL SELECT knob counterclockwise to the position marked Radiant Dual Surface Unit and Control Knob . Push in and turn the control knob to the desired setting. The unit will only heat the area inside the smaller circle.

OFF

LOHI

MED

Dual surface unit

Halogen Surface Unit

You may notice that the knob that

 

OFF

operates the halogen surface unit

LO

HI

is slightly harder to turn than the

 

 

knob for the radiant surface unit.

 

 

This is due to the difference in

 

 

design between the two controls.

 

 

NOTE:

The lowest three settings will produce no visible evidence of the surface unit being on although up to 11% of the total wattage is being generated. On the lowest settings, the percentage of power may not cause the HOT SURFACE lights to light. An indicator light near the control knobs will glow when any surface unit is on.

The surface UNIT ON light will glow for all positions except the off position.

8

The ten-position halogen control produces the following variation in cooking power.

Switch

Position

Brightness

Typical Heater

Settings

 

of Lamp

Power (%)

 

 

 

 

HI

10

Full

100

 

9

High

76

 

8

High

56

 

7

Medium

41

 

6

Medium

30

 

5

Low

23

 

4

Low

16

 

3

Invisible

11

 

2

Invisible

8

LO

1

Invisible

5

OFF

OFF

Invisible

0

If the halogen/radiant cooktop is connected to 208 volts, you will notice some increase in cooking times.