CONTROL KNOBS
Radiant Surface Unit
The control for the radiant surface |
| OFF |
unit can be set anywhere between LO | LO | HI |
|
| |
and HI for an unlimited number of |
|
|
heat settings.With the infinite switch |
|
|
the coil cycles on and off to maintain |
|
|
your selected control setting. |
| MED |
The control knob must be pushed in and turned from the OFF position. When the control knobs are in any position other than off, they may be turned without pushing down.
Be sure you turn the control knob off when you finish cooking. You will feel a “click” at the OFF position. Cooktop temperatures increase with the number of surface units that are on. With 3 or 4 units turned on, surface temperatures are high so be careful when touching the cooktop. The HOT SURFACE lights will remain lit after the surface unit is off until the surface is cool enough to touch.
Settings:
Medium
Medium
CAUTION: When the surface controls are turned off, the HOT SURFACE indicator light will remain lit until the cooktop surface has cooled to approximately 150°F. The glass ceramic surface will retain heat after the indicator light goes out. Use caution until the cooktop surface has had time to cool.
Radiant Dual Surface Unit and Control Knob
The right front radiant surface unit has 2 cooking sizes to select from so you can match the size of the unit to the size of the cookware you are using.
To use the large (9 inch) surface unit, turn the COIL SELECT knob clockwise to the position marked . Push in and turn the control knob to the desired setting. The unit will heat the entire area contained by the larger circle.
To use the small (6 inch) surface unit, turn the COIL SELECT knob counterclockwise to the position marked . Push in and turn the control knob to the desired setting. The unit will only heat the area inside the smaller circle.
OFF
LOHI
MED
Dual surface unit
Halogen Surface Unit
You may notice that the knob that |
| OFF |
operates the halogen surface unit | LO | HI |
is slightly harder to turn than the |
|
|
knob for the radiant surface unit. |
|
|
This is due to the difference in |
|
|
design between the two controls. |
|
|
NOTE:
•The lowest three settings will produce no visible evidence of the surface unit being on although up to 11% of the total wattage is being generated. On the lowest settings, the percentage of power may not cause the HOT SURFACE lights to light. An indicator light near the control knobs will glow when any surface unit is on.
•The surface UNIT ON light will glow for all positions except the off position.
8
The
Switch | Position | Brightness | Typical Heater |
Settings |
| of Lamp | Power (%) |
|
|
|
|
HI | 10 | Full | 100 |
| 9 | High | 76 |
| 8 | High | 56 |
| 7 | Medium | 41 |
| 6 | Medium | 30 |
| 5 | Low | 23 |
| 4 | Low | 16 |
| 3 | Invisible | 11 |
| 2 | Invisible | 8 |
LO | 1 | Invisible | 5 |
OFF | OFF | Invisible | 0 |
•If the halogen/radiant cooktop is connected to 208 volts, you will notice some increase in cooking times.