8REMOVE DUCT KNOCKOUT(S)

Installation Instructions

8REMOVE DUCT KNOCKOUT(S)

If recirculating, non-vented ductless (optional for JV5 Series models only), see note below and skip to Step 11 D and proceed. We do not recommend the recirculated configuration for JV6 Series models.

Using a flat blade screwdriver, remove the appropriate duct knockout(s) from the top or back of the hood.

9FOR 314X 10RECTANGULAR

DUCTED DISCHARGE

INSTALLATIONS ONLY:

Attach exhaust adaptor/damper over knockout opening with two exhaust adaptor screws. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.

314x 10Rectangular vertical discharge. Remove top rectangular duct knockout only.

7Round vertical discharge. Remove semi- circular duct knockout and top rectangular duct knockout.

314x 10Rectangular horizontal discharge. Remove rear rectangular duct knockout only.

Up to 1side-to-

Tape

side adjustment

 

Pivot

Top/back edge

 

 

Exhaust adaptor/damper

 

(vertical discharge position

 

shown)

NOTE: The exhaust adaptor/damper can be installed up to 1 inch on either side of the hood center to accommodate off-center ductwork. In extreme off- center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.

NOTE: If the hood is to be installed in a recirculating, non-vented ductless manner, order kit number WB02X10707 for 30hood models, or kit number WB02X10708 for 36hood models. These kits can

be ordered from your GE supplier. Skip to Step 11 D and proceed.

10FOR 7ROUND VERTICAL

DUCTED DISCHARGE

INSTALLATIONS ONLY:

Re-install the 7round exhaust adaptor with its screws, removed in Step 2 under the “Prepare the Hood” section.

7round 9FOR 31⁄4″ X 10″ RECTANGULAR exhaust adaptor

NOTE: The 7″ round exhaust adaptor can be installed up to 1″ on either side of the hood center to accommodate off-center ductwork. In extreme off-center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.