Installation Instructions

8REMOVE DUCT KNOCKOUT(S)

If recirculating, non-vented ductless (optional for JV5 Series models only), see note below and skip to Step 11 D and proceed. We do not recommend the recirculated configuration for JV6 Series models.

Using a flat blade screwdriver, remove the appropriate duct knockout(s) from the top or back of the hood.

9FOR 314X 10RECTANGULAR

DUCTED DISCHARGE

INSTALLATIONS ONLY:

Attach exhaust adaptor/damper over knockout opening with two exhaust adaptor screws. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.

314x 10Rectangular vertical discharge. Remove top rectangular duct knockout only.

7Round vertical discharge. Remove semi- circular duct knockout and top rectangular duct knockout.

314x 10Rectangular horizontal discharge. Remove rear rectangular duct knockout only.

Up to 1side-to-

Tape

side adjustment

 

Pivot

Top/back edge

 

 

Exhaust adaptor/damper

 

(vertical discharge position

 

shown)

NOTE: The exhaust adaptor/damper can be installed up to 1 inch on either side of the hood center to accommodate off-center ductwork. In extreme off- center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.

NOTE: If the hood is to be installed in a recirculating, non-vented ductless manner, order kit number WB02X10707 for 30hood models, or kit number WB02X10708 for 36hood models. These kits can

be ordered from your GE supplier. Skip to Step 11 D and proceed.

10FOR 7ROUND VERTICAL

DUCTED DISCHARGE

INSTALLATIONS ONLY:

Re-install the 7round exhaust adaptor with its screws, removed in Step 2 under the “Prepare the Hood” section.

7round exhaust adaptor

NOTE: The 7″ round exhaust adaptor can be installed up to 1″ on either side of the hood center to accommodate off-center ductwork. In extreme off-center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.

12

Page 12
Image 12
GE JV535 owner manual Remove Duct Knockouts, For 7″ Round Vertical Ducted Discharge Installations only