17SECURE HOOD

Installation Instructions

17SECURE HOOD

Slide the hood back against the wall. Tighten the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot.

Mounting screw (4)

Keyhole (4)

NOTE: DO NOT PUSH ON FAN BLADE. Pushing on the blade may cause it to interfere with other hood parts.

18CONNECT DUCTWORK TO HOOD

Use duct tape to make joints secure and air tight.

Duct tape

19INSTALL LIGHT BULBS

Purchase and install two PAR20, 50 W maximum halogen bulbs.

20FOLLOW ELECTRICAL CODE

Complete the electrical wiring according to National Electrical Code and local codes.

NOTE: This hood must be permanently grounded.

Connect house wiring (120 VAC) to hood wiring.

21CONNECT WIRING

Connect house black to hood black wire, house white to hood white wire, and house ground under green ground screw. Securely tighten the strain relief clamp onto the house wiring.

Green ground screw

22 REPLACE WIRING COVER

On models so equipped, replace the wiring cover or the bottom cover.

23REPLACE FILTERS

Make sure fan blade turns freely. The installation is complete. Turn on power at service panel, and test for proper operation.

TROUBLESHOOTING CHECKLIST

If the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems inadequate, check the following:

Knockouts not removed from hood.

Damper blade not opening.

Reduced airflow because the duct is too small or the duct length is too long.

The duct is blocked.

Undersized or restrictive wall or roof cap.