Power Supply

Power Supply

Safety

This downdraft vent must be supplied with 120V, 60Hz., and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.

Gas Cooktops

Do not leave gas or electrical connections within shaded area.

Instructions

If this vent is installed in combination with a gas cooktop, it may operate from the same duplex outlet.

Electric Cooktops

If this vent is installed in combination with a electric cooktop, the vent must operate from a separate 120V outlet.

A properly grounded 3-prong receptacle should be located

within reach of the vents’ two foot power cord.

–Locate the receptacle inside the cabinet on the right side

wall. The receptacle cannot be placed on the back of the

2912

34for 36models

2812for 30models

Gas CooktopsElectric Cooktops Electrical outlet

12above cabinet floor

Operating Instructions

cabinet wall where it may interfere with the downdraft

plenum. See illustration.

Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.

Ductwork Length and Dust Fittings

NOTE: Do not exceed 150maximum permissible equivalent lengths!

Flexible ducting: If flexible metal ducting is used, all equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.

DO NOT use flexible plastic ducting.

Add equivalent lengths for all duct pieces and transitions used to ensure that the duct run does not exceed the maximum 150′.

Duct

Equivalent

Duct

Equivalent

Duct

Equivalent

Pieces

Length*

Pieces

Length*

Pieces

Length*

 

 

 

 

314x 10

 

6Round

 

314x 10

 

to 6Round

12 ft.

1 ft. (per

 

Transition

5 ft.

 

Straight

foot length)

45° Elbow

90° Elbow

 

 

 

314x 10

 

314x 10

 

6Round

 

1 ft. (per

24 ft.

Wall Cap

21 ft.

Straight

foot length)

90° Flat Elbow

with Damper

 

 

 

 

 

6Round

 

314x 10

 

6

15 ft.

to 314x 10

7 ft.

Wall Cap

27 ft.

90° Elbow

 

Transition

 

with Damper

 

 

 

314x 10

 

 

 

6

9 ft.

to 6Round

5 ft.

6Round

20 ft.

45° Elbow

Transition

 

Roof Cap

 

 

 

 

 

6Round

 

 

 

314x 10

 

to 314x 10

20 ft.

6Round

 

 

Transition

 

16 ft.

 

24 ft.

90° Elbow

90° Elbow

 

Roof Vent

 

 

 

SHOULD NOT EXCEED 150 EQUIVALENT FT.

*Equivalent lengths of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance. See chart for CFM Duct Length.

13

Installation Instructions Troubleshooting Tips Customer Service

Page 13
Image 13
GE JVB37 Power Supply, Ductwork Length and Dust Fittings, NOTE Do not exceed 150′ maximum permissible equivalent lengths