Power Supply
Safety
This downdraft vent must be supplied with 120V, 60Hz., and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
Gas Cooktops
Do not leave gas or electrical connections within shaded area.
Instructions
If this vent is installed in combination with a gas cooktop, it may operate from the same duplex outlet.
Electric Cooktops
If this vent is installed in combination with a electric cooktop, the vent must operate from a separate 120V outlet.
■ A properly grounded |
within reach of the vents’ two foot power cord. |
■ |
wall. The receptacle cannot be placed on the back of the |
291⁄2″
34″ for 36″ models
281⁄2″ for 30″ models
Electrical outlet
12″ above cabinet floor
Operating Instructions
cabinet wall where it may interfere with the downdraft |
plenum. See illustration. |
Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
Ductwork Length and Dust Fittings
NOTE: Do not exceed 150′ maximum permissible equivalent lengths!
Flexible ducting: If flexible metal ducting is used, all equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.
DO NOT use flexible plastic ducting.
Add equivalent lengths for all duct pieces and transitions used to ensure that the duct run does not exceed the maximum 150′.
Duct | Equivalent | Duct | Equivalent | Duct | Equivalent |
Pieces | Length* | Pieces | Length* | Pieces | Length* |
|
|
|
| 31⁄4″ x 10″ |
|
6″ Round |
| 31⁄4″ x 10″ |
| to 6″ Round | 12 ft. |
1 ft. (per |
| Transition | |||
5 ft. |
| ||||
Straight | foot length) | 45° Elbow | 90° Elbow |
| |
|
| ||||
31⁄4″ x 10″ |
| 31⁄4″ x 10″ |
| 6″ Round |
|
1 ft. (per | 24 ft. | Wall Cap | 21 ft. | ||
Straight | foot length) | 90° Flat Elbow | with Damper |
| |
|
| ||||
|
| 6″ Round |
| 31⁄4″ x 10″ |
|
6″ | 15 ft. | to 31⁄4″ x 10″ | 7 ft. | Wall Cap | 27 ft. |
90° Elbow |
| Transition |
| with Damper |
|
|
| 31⁄4″ x 10″ |
|
|
|
6″ | 9 ft. | to 6″ Round | 5 ft. | 6″ Round | 20 ft. |
45° Elbow | Transition |
| Roof Cap | ||
|
|
| |||
|
| 6″ Round |
|
|
|
31⁄4″ x 10″ |
| to 31⁄4″ x 10″ | 20 ft. | 6″ Round |
|
| Transition |
| |||
16 ft. |
| 24 ft. | |||
90° Elbow | 90° Elbow |
| Roof Vent | ||
|
|
|
SHOULD NOT EXCEED 150 EQUIVALENT FT.
*Equivalent lengths of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance. See chart for CFM Duct Length.
13