PREPARE ELECTRICAL WIRING

Installation Preparation

PREPARE ELECTRICAL WIRING

FORPERSONAL SAFETY:Remove house

fuse or open circuit breaker before WARNINGbeginning installation. Do not use an extension cord or adapter plug with this

appliance.

Electrical Requirements

This appliance must be supplied with 120V,60 Hz., and connected to an individual properly grounded branch circuit, protected by a 15or 20 ampere circuit breaker or time delay fuse.

Wiring must be 2wire with ground.

If the electrical supply does not meetthe above requirements, call a licensed electrician before proceeding.

Grounding Instructions - Cable Direct

This appliance must be connected to a grounded metal, permanentwiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance.

Grounding Instructions - Power Cord Models

This appliance must be grounded, In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electric current, The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with local codes and ordinances.

WARNING

The improper connection of the

equipment grounding conductor can result in a risk of electric shock. Check

with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded,

 

I

I

\

_

/ ,'Ti

I

\ \

 

I

I

\

 

 

1-1/2" Dia.

 

 

 

Hole(Max.)

 

 

 

 

from

 

 

 

Cabinet

FigureE

White

Cabinet Preparation & Wire Routing

The wiring may enter the opening from either side, rear or the floor within the shaded area.

Cut a 1-1/2"max, dia, hole to admit the electrical cable. The hole must be free of sharp edges. If the cabinet wall is metal, the hole edge must be covered with a bushing.

Cable direct connections may pass through the same hole asthe drain hose and hotwater line, if convenient. If cabinetwall is metal, the hole edge must be covered with a bushing. NOTE: Power cords with plug must pass through a separate hole.

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher.

For cable direct connections the cable must be routed as shown in Figure E. Cable must extend a minimum of 24"from the rear wall.

For power cord connections, install a 3-prong ground- ing type receptacle. The power-supply receptacle for the appliance shall be installed in a cabinet or on a wall adjacent to the undercounter space in which the appliance is to be installed.

4