Installation Instructions
REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION
•Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back.
•The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section.
•Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:
0″ either side
3″ front and rear
•Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 52″.
•Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 INCHES.
Wire frame spacer
5.5″
(140 mm)
BATHROOM OR BEDROOM
INSTALLATION
•The dryer MUST be vented to the outdoors. See
EXHAUSTING THE DRYER.
•The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers) or NATIONAL FUEL GAS CODE, ANSI Z223 (for gas dryers).
UNDERCOUNTER INSTALLATION
If an undercounter installation is desired:
•No special dryer installation kit is required.
•If the dryer is installed alone, a minimum of 60 square inches of open area is required. If a washer and dryer are installed together,
a minimum of 120 square inches of open area
is required.
Dryer installed alone
Countertop and side cabinets
60 |
square |
inches |
min. |
open |
area |
Washer and Dryer installed together
Countertop and side cabinets
120 |
square |
inches |
min. open |
area |
MOBILE OR MANUFACTURED HOME INSTALLATION
•The installation must conform to the
MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART
NO. 501B.
•The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure. (See EXHAUSTING THE DRYER.)
•The vent MUST NOT be terminated beneath a mobile or manufactured home.
•The vent duct material MUST BE METAL.
•Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent .
•Provide an opening with a free area of at least 25 sq. in. for introduction of outside air into the dryer room.
13