Installation Instructions
FILTRATION DRAIN CONNECTION
Check and comply with local plumbing codes as you plan.
CAUTION: The options detailed below are the ONLY approved installation configurations. Do not use any drain saddle device.
NOTE: Failure to follow these Installation Instructions will void the warranty, and the installer will be responsible for any service, repair or damages caused thereby.
PREFERRED INSTALLATION: OPTION A—BASEMENT ACCESS INSTALLATION
Route the drain line DIRECTLY from the Reverse Osmosis system to a standpipe in the basement, bypassing the air gap provided in the faucet. The air gap installation is left to the discretion of the installer. The drain line may also be routed to a floor drain or washtub, provided that the air gap is maintained. Special air gap fittings are available to connect the drain line to the top of the standpipe.
Drain line from the Reverse Osmosis system
1″
1″ minimum air gap must be maintained
PREFERRED INSTALLATION: OPTION
Install a separate
Reverse Osmosis drain line
Optional disposer
15