3.4.5Discharge Screen (Strainer)

3.4.5Discharge Screen (Strainer)

A 30-mesh discharge screen (available as an accessory) located in the dis- charge piping will protect your process fluid should the pump be damaged. The installation of the screen is shown in Figure 3.3 (Discharge Screen Installation).

Victaulic Gasket

 

Discharge Screen

Pump

(Cup Must Point

 

Towards Pump)

Victaulic

Clamp

Figure 3.3

Discharge Screen

Installation