STEP 3 LEVEL

Installation Instructions

STEP 3 LEVEL

Use an adjustable wrench to turn the leveling legs and raise or lower the product.

Adjust carefully; the product should be level and plumb with cabinetry, and should align with adjacent toekick height.

Turn Right to Lower

Turn Left to Raise

If you skipped Step 2:

Select the hinge cover marked “R” or “L”, depending on door swing.

Peel backing off the tape inside the decorative hinge cover. Press and snap into position.

Snap the screw hole cover into place on the opposite side.

STEP 4 CONNECT POWER

Connect power cord plug to a properly grounded receptacle.

Check to make sure power is on by opening the door to see if interior light turns on.

STEP 5 SLIDE PRODUCT INTO

THE CUTOUT

Carefully, slide the unit into the opening. Be careful not to entangle the power cord.

Make certain that the door protrudes 1beyond the surrounding cabinets (1-7/8for custom frame models).

Check again to be sure the unit is level.

STEP 6 INSTALL NAMEPLATE

Follow instructions on the back page for installation of the Monogram nameplate.

STEP 7 SET TEMPERATURE CONTROLS

The temperature controls are preset. Refer to the Owner’s Manual for more information. Allow 24 hours for temperature to stabilize.

CUSTOM FRAME PANEL MODELS

Model ZDWI240WII and ZDBI240WII

These models require a custom panel frame surrounding the glass. There are two options: the panel may be 29-3/4or 30high. A 30panel requires a notch cut into the bottom of the panel to avoid interference with the hinges.

Rout the back side of the panel to the dimensions shown.

A custom handle of your choice or ZTBSS1 Tubular Handle must be installed before the panel is mounted onto

the door.

NOTE: The 4 corners of the routed areas

must be squared to fit the corners of the metal door frame.

Option 1

Option 2

 

23-1/8”

 

 

23-1/8”

 

2-1/4”

 

 

2-1/4”

 

 

wide,

 

 

 

 

 

all sides

25-1/4”

 

Rout the back

25-1/4”

 

Rout the

 

 

 

 

 

 

side of the

 

 

back side

 

29-3/4”

GLASS

30”

GLASS

opening 7/16”

of the

 

 

deep, 1-1/8” wide

 

 

opening

 

 

18-5/8”

 

18-5/8”

 

 

 

7/16”deep,

 

 

 

 

 

 

 

 

1-1/8” wide

 

 

2-1/2” at

 

 

 

 

 

 

 

 

 

 

bottom

 

 

 

3/4” Thick Custom Panel,

 

2-1/4”

 

2-1/4”

 

Back Side

 

 

NOTE: Right-hand models

1/8”

1/4”

 

 

Cut the notch

illustrated. Cut notches

 

 

 

 

1/8” deep, 1/4”

 

 

 

 

for hinge clearance on the

 

 

1/4”

wide and 1/4”

opposite side for left-hand

 

 

 

 

high

 

 

 

 

door swing.

 

 

 

 

 

Choose Option 1 or Option 2 panel size depending on cabinetry size or style.

NOTE: A solid panel that covers the door glass CANNOT be installed on these models.

Install the custom panel:

Open the door fully.

Remove the gasket surrounding the inside of the door to expose the existing screw holes for the custom panel.

Hold the custom frame panel against the door and align carefully, top to bottom and side to side. Mark screw hole locations on the back side of the panel.

Drill pilot holes in the back side of the custom panel. In hardwood, drill 3/32pilot holes. In softwood, drill 5/64holes.

Secure the prepared panel to the door using ten (10)

#8 x 5/8screws. Drive the screws through the door frame and into the wood.

Replace the gasket.