GE RGA620, RGA624 Safety Precautions, Cook Meat and Poultry THOROUGHLY…, Safety Instructions

Models: RGA624 RGA620

1 36
Download 36 pages 46.72 Kb
Page 4
Image 4

Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

SAFETY PRECAUTIONS

Be sure all packing materials are removed from the range before operating it to prevent fire or smoke damage should the packing material ignite.

Tips Installation Instructions Care and Cleaning Operating Instructions

Have the installer show you the location of the range gas cut-off valve and how to shut it off if necessary.

Have your range installed and properly grounded by a qualified installer, in accordance with the Installation Instructions. Any adjustment and service should be performed only by qualified gas range installers or service technicians.

Plug your range into a 120-volt grounded outlet only (on electric ignition models). Do not remove the round grounding prong from the plug. If in doubt about the grounding of the home electrical system, it is your personal responsibility and obligation to have an ungrounded outlet replaced with a properly grounded, three- prong outlet in accordance with the National Electrical Code NFPA–70 latest edition. In Canada, the appliance must be electrically grounded in accordance with the Canadian Electrical Code. Do not use an extension cord with this appliance.

Do not attempt to repair or replace any part of your range unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.

Locate range out of kitchen traffic path and out of drafty locations to prevent pilot outage (on standing pilot models) and poor air circulation.

Be sure your range is correctly adjusted by a qualified service technician or installer for the type of gas (natural or LP) that is to be used. Your range can be converted for use with either type of gas. See the Installation Instructions.

WARNING: These adjustments must be made by a qualified service technician in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow these instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.

After prolonged use of a range, high floor temperatures may result and many floor coverings will not withstand this kind of use. Never install the range over vinyl tile or linoleum that cannot withstand such type of use. Never install it directly over interior kitchen carpeting.

Do not leave children alone or unattended where a range is hot or in operation. They could be seriously burned.

Do not allow anyone to climb, stand or hang on the door, broiler door or range top. They could damage the range and even tip it over, causing severe personal injury.

Clean only parts listed in this manual.

Consumer Support Troubleshooting

COOK MEAT AND POULTRY THOROUGHLY…

Cook meat and poultry thoroughly—meat to at least an INTERNAL temperature of 160°F and poultry to at least an INTERNAL temperature of 180°F. Cooking to these temperatures usually protects against foodborne illness.

4

Page 4
Image 4
GE RGA620 Safety Precautions, Cook Meat and Poultry THOROUGHLY…, Safety Instructions, Consumer Support Troubleshooting

RGA624, RGA620 specifications

The General Electric (GE) RGA620 and RGA624 are advanced radiation survey meters designed for professionals in nuclear facilities, environmental monitoring, and emergency response. These devices offer robust performance and innovative features that enhance user experience and ensure precise radiation detection.

At the core of the RGA620 and RGA624 are highly sensitive Geiger-Müller (GM) tubes, which allow for the detection of alpha, beta, and gamma radiation. This versatility makes them suitable for a wide range of applications, from laboratory research to field measurements in emergency situations. Both models feature a broad energy response, enabling accurate detection across varying radiation energies.

One of the standout features of the RGA620 and RGA624 is their digital display, which provides clear and easily readable results. The intuitive interface allows users to quickly access measurement functions, change settings, and view real-time data. Alongside this, the devices are equipped with audible alarms, providing instant alerts when radiation levels exceed predefined thresholds, ensuring timely response during critical situations.

Both models utilize advanced data logging capabilities, enabling users to store measurement data for future analysis or compliance reporting. This feature is particularly valuable in regulatory environments where documentation of radiation levels is crucial. The RGA620 and RGA624 can also connect to external software for further data management, enhancing operational efficiency.

In terms of durability, the RGA620 and RGA624 are designed with rugged housing that meets stringent industrial standards. Their lightweight and portable design make them suitable for fieldwork, allowing professionals to conduct radiation surveys effortlessly. The devices are also designed for easy maintenance, with replaceable batteries and straightforward calibration processes.

Enhanced connectivity options, including USB ports, allow for easy data transfer and integration with other monitoring systems. This adaptability ensures that the RGA620 and RGA624 can be an integral part of a comprehensive radiation safety program.

Overall, the GE RGA620 and RGA624 are exemplary tools in radiation detection technology. Their combination of sensitivity, user-friendly features, and robust design make them essential for professionals working in environments where radiation monitoring is paramount. With these instruments, users can ensure safety, compliance, and effective management of radiation risks.