Safety Instructions

Installation of the range.

Read these instructions completely and carefully.

WARNING! INSTALLATION SAFETY INSTRUCTIONS (continued)

Instructions Care and Cleaning Operating Instructions

The ventilating hood must be constructed of sheet metal not less than 0.0122″ thick.

Install above the cooktop with a clearance of not less than 1/4″ between the hood and the underside of the combustible material or metal cabinet. The hood must be at least as wide as the appliance and centered over the appliance. Clearance between the cooking surface and the ventilation hood surface MUST NEVER BE

LESS THAN 24 INCHES.

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

If cabinets are placed above the range, allow a minimum clearance of 30″ between the cooking surface and the bottom of unprotected cabinets.

If a 30″ clearance between cooking surface and overhead combustible material or metal cabinets cannot be maintained,

protect the underside of the cabinets above the cooktop with not less than 1/4″

insulating millboard covered with sheet metal not less than 0.0122″ thick.

Clearance between the cooking surface and protected cabinets MUST NEVER BE LESS THAN 24 INCHES. The vertical distance from the plane of the cooking surface to the bottom of adjacent

overhead cabinets extending closer than

1″ to the plane of the range sides must not be less than 18″. (See the Dimensions and Clearances illustration in this section.)

CAUTION: Items of interest to children should not be stored in cabinets above a range or on the backsplash of a range—children climbing on the range to reach items could be seriously injured.

Installation

Dimensions and Clearances

Provide adequate clearances between the range and adjacent combustible surfaces.

Support Troubleshooting Tips

A

3934

36

24

26from wall to front of control panel

B

Minimum to

30

cabinets on

 

either side 18Minimum

of range

 

36

C

Minimum to wall on either side of range above 36height

13

Maximum depth for cabinets above range top

Consumer

D

24

0 clearance below cooking top and at rear of range

Models

A

B

C

D

 

 

 

 

 

20 Wide

20

20 38

2

39 12

24 Wide

24

24 38

0

4012

 

 

 

 

 

Page 24
Image 24
GE RGA620, RGA624 owner manual Dimensions and Clearances, Safety Instructions, Installation, Support Troubleshooting Tips

RGA624, RGA620 specifications

The General Electric (GE) RGA620 and RGA624 are advanced radiation survey meters designed for professionals in nuclear facilities, environmental monitoring, and emergency response. These devices offer robust performance and innovative features that enhance user experience and ensure precise radiation detection.

At the core of the RGA620 and RGA624 are highly sensitive Geiger-Müller (GM) tubes, which allow for the detection of alpha, beta, and gamma radiation. This versatility makes them suitable for a wide range of applications, from laboratory research to field measurements in emergency situations. Both models feature a broad energy response, enabling accurate detection across varying radiation energies.

One of the standout features of the RGA620 and RGA624 is their digital display, which provides clear and easily readable results. The intuitive interface allows users to quickly access measurement functions, change settings, and view real-time data. Alongside this, the devices are equipped with audible alarms, providing instant alerts when radiation levels exceed predefined thresholds, ensuring timely response during critical situations.

Both models utilize advanced data logging capabilities, enabling users to store measurement data for future analysis or compliance reporting. This feature is particularly valuable in regulatory environments where documentation of radiation levels is crucial. The RGA620 and RGA624 can also connect to external software for further data management, enhancing operational efficiency.

In terms of durability, the RGA620 and RGA624 are designed with rugged housing that meets stringent industrial standards. Their lightweight and portable design make them suitable for fieldwork, allowing professionals to conduct radiation surveys effortlessly. The devices are also designed for easy maintenance, with replaceable batteries and straightforward calibration processes.

Enhanced connectivity options, including USB ports, allow for easy data transfer and integration with other monitoring systems. This adaptability ensures that the RGA620 and RGA624 can be an integral part of a comprehensive radiation safety program.

Overall, the GE RGA620 and RGA624 are exemplary tools in radiation detection technology. Their combination of sensitivity, user-friendly features, and robust design make them essential for professionals working in environments where radiation monitoring is paramount. With these instruments, users can ensure safety, compliance, and effective management of radiation risks.