Microwaving

Advantium Oven

Time Cook

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

 

OVEN LIGHT

 

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

 

 

 

 

 

 

RECIPE

 

 

 

 

 

 

RN

TOS

ELEC

TU

T

P

TER

R

ESS TOEN

START

PAUSE

CLEAR

OFF

Use Time Cook to microwave food that is not in the recipe section.

The power level is automatically set at high, but you can change it for more flexibility.

1.Press the MICROWAVE/OVEN LIGHT button.

2.Turn the dial to TIME COOK and press the dial to enter.

3.Turn the dial to set the time and press the dial to enter.

4.To change the power level if you don’t want full power, press the POWER LEVEL button. Turn the dial to select. Press the dial to enter.

5.Press the dial or the START/ PAUSE button to start cooking.

You may open the door during TIME COOK to check the food. Close the door and press START to resume cooking.

Micro

Express

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

 

OVEN LIGHT

 

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

 

 

 

 

 

 

RECIPE

 

 

 

 

 

 

Press MICRO EXPRESS repeatedly for 30 second increments of microwave cooking time. Oven starts immediately.

O

SEL

 

NT

START

UR

ECT

T

 

PAUSE

 

 

CLEAR

P

TER

OFF

R

 

ESS TOEN

 

Microwave power level

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

 

OVEN LIGHT

 

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

 

 

 

 

 

 

RECIPE

 

 

 

 

 

 

RN

TOS

ELEC

TU

T

P

TER

R

ESS TOEN

START

PAUSE

CLEAR

OFF

1.First, follow directions for TIME COOK, TIME DEFROST or

MICRO EXPRESS.

2.Press the POWER LEVEL button.

3.Turn the dial clockwise to increase and counterclockwise to decrease the power level. Press the dial

to enter.

4.Press the dial or the START/PAUSE button to start cooking.

You can change the power level before or during a cooking program (except when using MICRO EXPRESS).

Here are some examples of uses for various power levels:

High 10: Fish, bacon, vegetables, boiling liquids.

Med-High 7: Gentle cooking of meat and poultry; baking casseroles and reheating.

Medium 5: Slow cooking and tenderizing for stews and less tender cuts of meat.

Low 2 or 3: Defrosting; simmering; delicate sauces.

Warm 1: Keeping food warm; softening butter.

Cooking tips

When cooking bacon, layer strips on a plate. Cover each layer with a paper towel.

When cooking vegetables, use a microwave-safe casserole or bowl. Cover with a lid or vented plastic wrap.

For frozen vegetables, follow the package instructions for adding water.

For fresh vegetables, add two tablespoons of water for each serving.

23

Page 23
Image 23
GE SCB2001, SCB2000 owner manual Time Cook, Micro Express, Microwave power level, Cooking tips

SCB2001, SCB2000 specifications

The GE SCB2000 and SCB2001 are advanced power circuit breakers designed to meet the demanding requirements of modern electrical networks. Tailored for medium voltage applications, these compact devices provide reliable protection and control for electrical systems.

One of the standout features of the SCB2000 and SCB2001 is their ability to deliver high performance in a small footprint. This is particularly beneficial in urban environments where space can be a constraint. The innovative design incorporates state-of-the-art materials and manufacturing techniques, ensuring durability and efficiency.

A key technology integrated into these circuit breakers is the use of microprocessor-based control systems. This advancement allows for enhanced monitoring and protection functionalities. The digital platform enables users to set and customize protection settings easily, ensuring that the circuit breakers adapt to specific operational needs. Additionally, this technology supports advanced communication protocols, allowing for seamless integration into smarter grid systems.

Safety is paramount in any electrical system, and the SCB2000 and SCB2001 provide excellent safety features. They include arc detection and interruption capabilities, which significantly reduce the risk of major electrical faults. Moreover, these breakers are designed with an insulating medium that improves their performance while adhering to environmental regulations, further promoting workplace safety.

The breakers also boast flexibility in their application. They can be used in various sectors, including utilities, industrial plants, and commercial buildings. This versatility makes them a suitable choice for operators looking to upgrade their existing infrastructure or set up new projects.

Another characteristic that sets the SCB2000 and SCB2001 apart is their low maintenance requirements. With robust engineering and a focus on reliability, these devices minimize the need for regular servicing, thereby reducing operational costs for businesses.

In summary, the GE SCB2000 and SCB2001 circuit breakers offer a blend of compact design, innovative technology, and safety features, making them ideal solutions for modern electrical applications. Their high performance and adaptability ensure they meet the evolving demands of the energy sector, positioning them as a smart choice for any organization looking to enhance their electrical systems.