IMPORTANT SAFETY INSTRUCTIONS

Advantium Oven

WARNING! To reduce the risk of burns, electric shock, fire, injury to persons, or exposure to excessive microwave energy:

SAFETY PRECAUTIONS

Read all instructions before using this appliance.

When using electrical appliances, basic safety precautions should be followed, including the following:

Read and follow the specific precautions in the PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY section on page 2.

Be sure your appliance is properly installed and grounded by a qualified technician in accordance with the provided installation instructions.

Install or locate this appliance only in accordance with the provided installation instructions.

Some products such as whole eggs and sealed containers—for example, closed jars—will explode and should not be heated in this oven. Such use of the oven could result in injury.

Do not mount this appliance over a sink.

This oven is not approved or tested for marine use.

This oven is UL listed for standard wall installation.

Do not operate this appliance if it has been damaged or dropped.

As with any appliance, close supervision is necessary when used by children.

Use this appliance only for its intended use as described in this manual.

Do not use corrosive chemicals or vapors in this appliance.

This oven is specifically designed to heat, dry or cook food, and is not intended for laboratory or industrial use.

This appliance should be serviced only by qualified service personnel. Contact nearest authorized service facility for examination, repair or adjustment.

Do not cover or block any openings on the appliance.

Do not store this appliance outdoors. Do not use this product near water—for example, in a wet basement, near a swimming pool or near a sink.

See door surface cleaning instructions in the Care and Cleaning of the Oven section of this manual.

To reduce the risk of fire in the oven cavity:

Do not overcook food. Carefully attend appliance if paper, plastic or other combustible materials are placed inside the oven while cooking.

Remove wire twist-ties and metal handles from paper or plastic containers before placing them in the oven.

Do not use the oven for storage purposes. Do not leave paper products, cooking utensils or food in the oven when not in use.

If materials inside the oven should ignite, keep the oven door closed, turn the oven off and disconnect the power cord, or shut off power at the fuse or circuit breaker panel. If the door is opened, the fire may spread.

3

Page 3
Image 3
GE SCB2001, SCB2000 owner manual Safety Precautions

SCB2001, SCB2000 specifications

The GE SCB2000 and SCB2001 are advanced power circuit breakers designed to meet the demanding requirements of modern electrical networks. Tailored for medium voltage applications, these compact devices provide reliable protection and control for electrical systems.

One of the standout features of the SCB2000 and SCB2001 is their ability to deliver high performance in a small footprint. This is particularly beneficial in urban environments where space can be a constraint. The innovative design incorporates state-of-the-art materials and manufacturing techniques, ensuring durability and efficiency.

A key technology integrated into these circuit breakers is the use of microprocessor-based control systems. This advancement allows for enhanced monitoring and protection functionalities. The digital platform enables users to set and customize protection settings easily, ensuring that the circuit breakers adapt to specific operational needs. Additionally, this technology supports advanced communication protocols, allowing for seamless integration into smarter grid systems.

Safety is paramount in any electrical system, and the SCB2000 and SCB2001 provide excellent safety features. They include arc detection and interruption capabilities, which significantly reduce the risk of major electrical faults. Moreover, these breakers are designed with an insulating medium that improves their performance while adhering to environmental regulations, further promoting workplace safety.

The breakers also boast flexibility in their application. They can be used in various sectors, including utilities, industrial plants, and commercial buildings. This versatility makes them a suitable choice for operators looking to upgrade their existing infrastructure or set up new projects.

Another characteristic that sets the SCB2000 and SCB2001 apart is their low maintenance requirements. With robust engineering and a focus on reliability, these devices minimize the need for regular servicing, thereby reducing operational costs for businesses.

In summary, the GE SCB2000 and SCB2001 circuit breakers offer a blend of compact design, innovative technology, and safety features, making them ideal solutions for modern electrical applications. Their high performance and adaptability ensure they meet the evolving demands of the energy sector, positioning them as a smart choice for any organization looking to enhance their electrical systems.