Installation Instructions

POWER CONNECTION CHART

Power Cord Connections

230/208 Volt

 

 

 

Power Supply Kits

 

 

 

with Current Leakage

Wall Plug

 

Heater Wattage

Detection Device

Configuration

Circuit Protective Device

@ 230/208 Volts

 

 

 

 

 

RAK3153

 

Tandem

15-Amp Time-Delay Fuse or Breaker

2.55/2.09 KW

RAK3203

 

Perpendicular

20-Amp Time-Delay Fuse or Breaker

3.45/2.82 KW

RAK3303*

 

Large Tandem

30-Amp Time-Delay Fuse or Breaker

5.00/4.10 KW

 

 

 

 

 

Direct Connections

230/208 Volt

Heater Wattage

 

Power Supply Kits

@ 230/208 Volts

Circuit Protective Device

 

 

 

RAK4157

2.55 KW/2.09 KW

15-Amp Time-Delay Fuse or Breaker

RAK4207

3.45 KW/2.82 KW

20-Amp Time-Delay Fuse or Breaker

RAK4307

5.00 KW/4.10 KW

30-Amp Time-Delay Fuse or Breaker

 

 

 

265 Volt

Heater Wattage

 

Power Supply Kits

@ 265 Volts

Circuit Protective Device

 

 

 

RAK5172

2.55 KW

15-Amp Time-Delay Fuse or Breaker

RAK5202

3.45 KW

20-Amp Time-Delay Fuse or Breaker

RAK5302*

5.00 KW

30-Amp Time-Delay Fuse or Breaker

 

 

 

* Not approved for use on 7000 BTUH units.