e

GE is . . . Sports Lighting!

Lamp Specification—The UltraSport floodlight takes advantage of metal halide lamp technology, proven by decades of use in all types of lighting application. It uses an advanced generation of lamps specifically designed for use in sports lighting. Offered in a choice of 2000, 1500 or 1000 watts, these white light sources feature a double-ended design without an outer bulb, and provide an average rated life of 3000, 6000 and 10,000 hours, respectively.

These advanced lamps also provide excellent color rendering with a 4000 degree Kelvin color temperature. They are designed for an orientation of horizontal plus or minus 4 degrees, and have no tilt factor.

 

 

 

 

 

 

LAMP DATA

Metal Halide

Metal Halide

 

2000 Watt Double-Ended

1500 Watt Double-Ended

 

 

GE Lamp Number

MQI/2000/T9/40

MQI/1500/T8/40

 

Catalog Number—OSRAM Sylvania

M2000T9/DE

M1500/T9/DE

 

ANSI Designation

U134

U133

 

Burning Position

Horizontal ± 4 Degrees

Horizontal ± 4 Degrees

 

MOL

10.00 Inches (254mm)

10.00 Inches (254mm)

 

LCL

5.00 Inches (127mm)

5.00 Inches (127mm)

 

Arc Length

4.25 Inches (108mm)

4.25 Inches (108mm)

 

Base

Ceramic #10 Spade

Ceramic #8-10 Spade

 

Lamp Volts

250 ± 10 Volts

265 ± 10 Volts

 

Lamp Current

8.5 Amps

6.3 Amps

 

Ignitor Pulse (Peak)

4000-5000 Volts

4000-5000 Volts

 

Pulse Width @ 3600 volts

One Microsecond

One Microsecond

 

Minimum Pulse Required

4000 Volts

4000 Volts

 

Initial Lumens

200,000

160,000

 

 

Lumens at 100 Hours

100%

100%

 

 

Lumens at 40% Rated Life

85%

85%

 

 

Average Rated Life

3000 Hours

6000 Hours

 

Color Temperature

4000° Kelvin

4000° Kelvin

 

CRI

RA=65+

RA=65+

 

Hot Restart Capability

Yes

Yes

 

Lamp Seal Temperature

Not to exceed 450 degrees C.

Not to exceed 450 degrees C.

 

Bulb Wall Temperature

Not to exceed 950 degrees C.

Not to exceed 950 degrees C.

 

 

 

 

 

Lamp Installation—UltraSport floodlights are shipped with lamps installed.

The double-ended metal halide lamp mounts transversely to a specific orientation by inserting the lamp ends into pre-focussed ceramic holders. It is held in place by stainless steel spring clips that snap/ lock in place. The electrical connection of the lamp is separate from the mechanical support, and is made by connecting the spade ended-lamp leads to the socket terminals and tightening with a screwdriver.