e
Ultra✭SportTM Floodlight
Ballast
GE AccuwattTM 2000, 1500 and 1000 watt
Ballast dielectric material is rated for a 200 degree C maximum operating temperature.
Every ballast undergoes a 2500 volt RMS “High Pot” and a 10KV “til” test in accordance with ANSI C82.4, C82.6 and C92.1 specifications. The ballast circuits are also designed to sustain a nominal lamp over a line voltage dip of 50% for up to four seconds when operating at nominal line voltage according to ANSI specification C82.6.
|
|
| % Allow- |
|
|
|
|
|
|
|
|
| able Line | Line |
| Power | Line | % Allow- | |
|
| Line | Voltage | Operating | Line | Factor | Starting | able Line | |
| Watts | Volts | Variation | Amperes | Watts | % | Amperes | Voltage Dip | |
2000 | 208 |
| 11.2 | 2125 |
| 10.0 |
|
| |
| *25°C | 240 |
| 9.5 | 2115 |
| 8.5 |
|
|
| Max | 277 |
| 8.3 | 2115 |
| 7.2 |
|
|
| Ambient | 347 | ±10 | 6.6 | 2122 | 90+ | 5.6 | 50 |
|
|
| 480 |
| 4.8 | 2132 |
| 4.4 |
|
|
| 1500 | 120 |
| 14.4 | 1630 |
| 11.2 |
|
|
| *40°C | 208 |
| 8.5 | 1630 |
| 6.9 |
|
|
| Max | 240 |
| 7.3 | 1630 |
| 5.6 |
|
|
| Ambient | 277 | ±10 | 6.3 | 1630 | 90+ | 4.7 | 50 |
|
|
| 347 |
| 4.8 | 1620 |
| 3.9 |
|
|
|
| 480 |
| 3.7 | 1630 |
| 2.8 |
|
|
| 1000 | 120 |
| 9.0 | 1080 |
| 6.6 |
|
|
| *40°C | 208 |
| 5.4 | 1070 |
| 4.1 |
|
|
| Max | 240 | ± | 4.8 | 1080 | 90+ | 3.5 | 50 |
|
| Ambient | 237 |
| 4.1 | 1080 |
| 2.9 |
|
|
|
| 347 |
| 3.6 | 1070 |
| 2.9 |
|
|
|
| 480 |
| 2.6 | 1088 |
| 1.8 |
|
|
NOTE: For 50Hz voltages, contact factory. *See ballast table for wattage limitations.
The ballast circuit will reliably start and stabilize a nominal lamp in ambient temperatures down to
Ballast
Optional Instant Hot
Optional System 2TM
The 2000/1500 watt and 1500/1000 watt system choices are available for separate game time and practice light levels.
9