Installation Options

COOKTOP INSTALLATION WITH A

36MONOGRAM DOWNDRAFT VENT,

MODEL ZVB36

The installation of the downdraft vent with this cooktop requires careful consideration. Both the cooktop and the vent must be installed according to each specific installation instruction.

COOKTOP REQUIREMENTS

The countertop must have a deep flat surface to accommodate the cooktop and vent. Countertops with a rolled front edge and backsplash will not provide the flat surface area required.

Review the illustration to determine the countertop surface requirements.

All cutout clearances for this installation must be observed.

36-3/4

3/8

21-11/16

cutout

depth34cooktop and vent area cutout

7/16cooktop overlap (1-1/4at center)

3/8

1/8gap

23-5/16total flat surface required at center

3-3/8min. cooktop cutout to rear vertical combustible surface

Front edge of countertop 2-1/2min. clearance

to cutout

12min. cutout to

wall, both sides

BASE CABINET REQUIREMENTS

The combined installation will fit in a standard 24deep base cabinet. Use a 36or wider base cabinet.

The vent housing, blower and ductwork will occupy the base cabinet.

POWER SUPPLY

If local codes permit, the vent and cooktop may operate from the same 120V, 15 amp duplex outlet. Locate the gas and electrical supply as shown on page 8.