Installation Instructions

MOBILE HOME INSTALLATION

ROUGH-IN DIMENSIONS

1. Dryer MUST be exhausted outside (outdoors, not

beneath the mobile home) using metal ducting that will

not support combustion. Metal ducting must be 4″

(10.16 cm) in diameter with no obstructions. Rigid metal

duct is preferred.

2. If the dryer is exhausted through the floor, the exhaust

system MUST NOT terminate beneath the mobile

home. Termination MUST be securely fastened to the

mobile home structure.

3. When installing a gas dryer into a mobile home, a

provision must be made for outside make-up air. This

provision is to be not less than twice the area of the dryer

exhaust outlet.

4. Gas dryers MUST be fastened to the floor using Mobile

Home Installation Kit Pub. No. 14–D346–33.

5. See the Exhaust System Requirements section for other

important venting information.

6. Installation MUST conform to current Manufactured

26 7/8

(68.3 cm)

Electrical connection

2 9/16

(6.5 cm)

139/16(34.5 cm)

3/16(0.48 cm) Dia.

3 3/4gas pipe

(9.5 cm)

Under

counter

345/8(87.9 cm)

36

(91.5 cm)

1(2.54 cm)

Home Construction & Safety Standard (which is a

Federal Regulation Title 24 CFR—Part 32–80) or,

when such standard is not applicable, with American

National Standard for Mobile Homes, ANSI/NFPA No.

501B. In Canada, the CSA Z240 is applicable.

Correct

Do

Incorrect

Don’t

Don’t

Don’t

The dryer is designed under ANSI Z 21.5.1.

REAR VIEW

47 1/2

(120.7 cm)

3/4(1.9 cm)

Door open

90˚

4 3/8

 

(11.1 cm)

 

Optional

 

vent knockout

 

25 3/4

 

(65.4 cm)

3 3/4

 

 

(9.5 cm)

SIDE VIEW