CONDENSATE

CONDENSATE

EVAPORATOR

ON

AUTO

POWER

ON

OFF

Power Switch Power Switch Condensate Evaporator Switch

The Power Switch is the ON/OFF switch for the cooling system. When first turning the unit on, there is a safety delay of 5 minutes. On the temperature display, a red LED light will light up beside WINE to indicate that start-up has been initiated and that that the thermostat is reading the liquid temperature. After 5 minutes, the red LED light beside ON will light up.

Condensate Evaporator Switch Manual background

The ON position of the Condensate Evaporator Switch activates the heating element whenever water is present in the evaporator pan. The AUTO position of the Condensate Evaporator Switch activates the heating element at regular intervals to remove excess water from the evaporator pan, as needed.

In most environments, the Condensate Evaporator Switch should be kept in the ON position. If your wine vault is located in a dry climate, excess water may not accumulate in the evaporator pan. In this case, turn the Condensate Evaporator Switch to the AUTO setting to save electricity.