GE Monogram ZBD5700 manual Removing and Cleaning the Spray Arms and Glass Trap, Care and Cleaning

Models: ZBD5600 ZBD5700 ZBD5900

1 28
Download 28 pages 30.1 Kb
Page 16
Image 16
Removing

Care and Cleaning

Dishwasher

Removing

and Cleaning

the Spray

Arms and

Glass Trap

Periodically, remove and clean the spray arms to make sure that none of the nozzles have become blocked.

To remove the lower spray arm, grasp the center of the spray arm and pull upwards, it will unclip. When replacing, make sure the spray arm is fully seated.

The plastic cone on the underside of the spray arm can be detached by unscrewing it counterclockwise.

To remove the upper spray arm, carefully unscrew the spray arm from the plastic tower. To achieve this, hold the inner tower steady and unscrew the spray arm clockwise. To replace the spray arm, carefully screw the spray arm counterclockwise onto the inner tower.

To clean the upper and lower spray arms, rinse them under running water and make sure spray nozzles are clear.

The glass trap is located in the stainless steel filter at the base of your dishwasher. The glass trap is used to collect larger food items and other foreign objects, which may be too big to pass through the drain pump. For best wash performance, check the glass trap occasionally.

To remove the glass trap, twist the two vertical handles counterclockwise, rotate the glass trap and lift. To clean the glass trap, empty and rinse thoroughly. To replace, reverse these steps making sure the glass trap locks into place.

Pull up to remove

Rotate counterclockwise to remove cone

Rotate counterclockwise and lift to remove glass trap

16

Page 16
Image 16
GE Monogram ZBD5700, ZBD5900 Removing and Cleaning the Spray Arms and Glass Trap, Care and Cleaning, Pull up to remove