Dimensions and Specifications (in inches)

34"-35"

12-1/8" min.

20-1/4"

34" min.

adj. to

22-1/2" min.*35" max.

*Add 2-1/2" to depth if outlet

is located directly behind compactor

12"

Adjustable base Dimensions and Specifications (in inches) 2-3/4" to 4-1/4"

Custom Panel Dimensions

The drawer panel size varies depending on applcation.

 

 

 

 

 

3/4" Custom

24-1/2"

1/4" Custom

24-3/4"

3/4" Custom

25-13/16"

Drawer

Drawer

Drawer

Panel With

 

Panel

 

Panel

 

Custom

 

 

 

 

 

Handles

 

 

 

 

 

 

 

11-11/16"

 

12"

12"

This Monogram compactor has a white control panel and is supplied with a white/black reversible aluminum front drawer panel. This panel can be reversed to reveal the opposite color side.

The design will accept a custom front drawer panel to match surrounding cabinetry. A 1/4"-thick panel can replace the aluminum panel and will slide into the existing trim on the drawer front. A 3/4"-thick panel can replace the aluminum panel and existing trim for a trimless appearance.

The adjustable base allows the toekick depth to match surrounding cabinetry. This compactor is designed as a built-in appliance only. It may be located in any convenient space under a countertop. DO NOT OPERATE FREE-STANDING because the compactor will tip over when the drawer is pulled out.

1/4"-Thick Custom Panel

Cut the panel to size and install.

3/4"-Thick Custom Panel

The custom panel should be constructed in the same manner as typical cabinet doors. Cut edges must be finished on all sides.

3/4"-Thick Custom Panel with Custom Handle

The supplied handle may be replaced with a custom handle of your choice.

Additional Specifications

A 115 Volt, 60 Hz. power supply is required. An individual properly grounded branch circuit protected by a 15- or 20-amp circuit breaker or time delay fuse is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical outlet location is critical for proper cord storage when compactor is installed.

If the compactor is to be located in or near a corner of base cabinets, allow 2" minimum clearance from the corner to prevent interference with adjacent door handles.

Note:

If cord is to be plugged in directly behind compactor add 2-1/2" to overall depth in order to allow proper clearance for the electrical cord.

Listed by

Underwriters

RLaboratories

For answers to your Monogram,® GE Profileor
GE® appliance questions, visit our website at
GEAppliances.com or call GE Answer Center®

Specification Revised 9/03

service, 800.626.2000.

160001

Page 1
Image 1
GE Monogram dimensions ZCG3100VBB - GE Monogram Built-In Compactor, Dimensions and Specifications in inches, service