GE Monogram ZGU375NS Installation With Warming Drawer, IMPORTANT Base Cabinet Requirements

Models: ZGU375LS ZGU375NS

1 12
Download 12 pages 51.88 Kb
Page 10
Image 10
Installation With Warming Drawer

Installation With Warming Drawer

Installation Options

Stainless Steel G a s Cooktop

Cooktop Installation Over a 30" Monogram Warming Drawer, models ZTD910.

These cooktops may be installed over a 30" Warming Drawer. Both the cooktop and the warming drawer must be installed according to each specific installation instruction. For accurate planning, review the Warming Drawer Installation Instructions in advance, order Pub. No. 49-8937.

Install 2x4 or 2x2 Anti-Tip Block

Against Rear Cabinet Wall 9" From

Cutout Floor to Bottom of Block

Cooktop 35-5/16"

9"

Allow 2" clearance between the cooktop bottom and the top of the cutout, or 7-1/2" from the top of the countertop as illustrated.

Power Supply:

If local codes permit, the cooktop and warm- ing drawer may operate from the same 120V duplex outlet. See page 6.

1-1/2" Cabinet Top

25"

18-7/8"

2-3/4" Min.

 

7-1/2" Min.

36"

Countertop

23-1/2" Min.

9-1/4"

28-1/2"

Height

NOTE: When installing a Monogram Warming Drawer below a cooktop, a solid barrier must be installed at least 1" from the lowest point of the bottom of cooktop burner box to the top of cutout. See Warming Drawer Installation Instructions for details.

IMPORTANT: Base Cabinet Requirements

for Combined Installation

A 42" wide base cabinet should be used. Narrow custom doors or decorative stiles can be used to fill the 6" gap on each side of the warming drawer.

30" or 36" base cabinets are not recommended.

 

 

 

 

 

 

Install

 

 

 

 

 

 

2x4 or 2x2

 

 

 

 

 

 

Anti-Tip Block

 

 

 

 

 

 

 

 

 

 

 

 

Against Rear

9"

 

 

Cabinet Wall

 

 

 

 

 

 

9" From Floor

 

 

 

 

 

 

 

 

 

 

 

 

to Bottom

 

 

 

 

 

 

of Block

2x4 or 2x2

IMPORTANT: Base Cabinet Requirements Runners or Solid for Combined Installation

Bottom, 25" on Center

NOTE: The support must be level, rigidly mounted and capable of supporting 150 lbs.