GE Monogram ZISW36D INSTALLATION ~QUImMENTS, PmPAWTION, WORTANT.. .Please Read CarefuUy, Leveling

Models: ZISW36D ZIS36N ZISB36D

1 24
Download 24 pages 7.75 Kb
Page 17
Image 17
INSTALLATION ~QUImMENTS

INSTALLATION ~QUImMENTS

WORTANT.. .Please Read CarefuUy.

How to connect electricity

For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with

athree-prong (grounding) plug which mates with a standard three-prong (grounding) wall outlet (Fig. 1) to minimize the possibility of electric shock hazard from this appliance.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE T~RD (GROUND) PRONG FROM THE POWER CO~.

DO NOT USE AN ADAPTER PLUG TO CONNECT THE REFRIGERATOR TO A TWO-PRONG OUTLET.

DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.

Fig. 1

INSURE PROPER GROUND EXISTS BEFORE USE

The refrigerator should always be plugged into its own individual electrical outlet—(] 15 volt, 60 Hertz, single phase AC—protected by a 20-amp time delay fuse or circuit breaker). This is recommended for best performance and to prevent overloading house wiring circuits, which could cause a fire

Have wall outlet and circuit checked by a qualified electrician to make sure outlet is properly grounded.

Where a standard two-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded three-prong wall outlet.

hazard from overheating wires.

IMPORTANT: The water line and the electrical outlet must be installed in the exact location described in the Installation Instructions (Pub. No. 49-6445).

PmPAWTION

Refrigerator Location

Install the refrigerator on a floor strong enough to support it when it is fully loaded.

Do not install refrigerator where temperature will go below 60°F. because it will not run often enough to maintain proper temperatures.

Clearances

If the refrigerator is to be installed in a corner, allow 2“ between the hinges of the refrigerator and the wall to assure a 90° door opening capability.

No other clearances at top, sides or back are required.

Leveling

This model has 4-point leveling. All four corners are

supported by leveling legs. The front wheels are non-4 adjustable; they are only used for positioning the unit.

To level the back of the unit, turn hex nut located

above the front wheels.

To level the front of the unit, use a 1 Y4° open end wrench and adjust the leveling legs.

Turn hex nut or front leveling leg clockwise to raise the unit, counter-clockwise to lower the unit.

See the Installation Instructions (Pub. No. 49-6445) for complete directions.