ADDITIONAL SWITCHING OPTIONS

The underside of the 2x2 DPKVM Switch features a DIP switch bank that is used to configure additional features. DIP switch 3 is used to control the function of Contact Closure-type remote controls on the rear panel.

This port can be configured to accept additional switching devices

ON

OFF

1

2 3 4

1

2

3

4

DIP Switch 3

IR Channel

IR Channel

Remote/Closure

Not Used

Enabling DIP switch 3 will allow the user to utilize a contact closure type of remote control such as Gefen product # EXT-RMT-2x2 to initiate input switching. By default, this switch is in the OFF position and will rely on the standard switching methods outlined previously in this manual.

DIP Switch 4

Not Used

Note: After resetting DIP switches, the unit must be power-cycled.