RS-232 SERIAL CONTROL

5 4 3 2 1

1 2 3 4 5

9 8 7 6

6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface

This feature allows for easy integration into automated systems capable of transmitting RS-232 commands. Please use the settings listed below to configure the RS-232 port of the user’s system.

Transmitting the appropriate numeric ASCII character will simulate key presses on the RMT-4IR remote control.

Binary Table

ASCII

RMT-4IR

Binary

 

Button

 

 

 

 

1

1

0011 0001

2

2

0011 0010

3

3

0011 0011

4

4

0011 0100

RS-232 Settings

 

Bits per second

19200

Data bits

8

Parity

None

Stop bits

1

Flow Control

None

13

Page 16
Image 16