RS-232 SERIAL CONTROL
5 4 3 2 1 | 1 2 3 4 5 |
9 8 7 6 | 6 7 8 9 |
Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the
This feature allows for easy integration into automated systems capable of transmitting
Transmitting the appropriate numeric ASCII character will simulate key presses on the
Binary Table
ASCII | Binary | |
| Button |
|
|
|
|
1 | 1 | 0011 0001 |
2 | 2 | 0011 0010 |
3 | 3 | 0011 0011 |
4 | 4 | 0011 0100 |
|
|
Bits per second | 19200 |
Data bits | 8 |
Parity | None |
Stop bits | 1 |
Flow Control | None |
13