7500EXL Extended Life Generator
GENERATOR ADAPTER CORD SET
The generator is equipped with a 25’ generator adapter cord set designed for a 240 Volt, 30 Amp grounded neutral circuit (Figure 10).The generator adapter cord set provides a convenient supply of emergency power into your dwelling so that your generator can be operated safely outside.
Figure 10 — Generator Adapter Cord Set
The maximum load on each outlet is 20 Amps.The maximum total load on both yellow wire outlets or both black wire outlets is 30 Amps.
NOTE: Follow all safety precautions when connecting any extension cord or device to the generator.
RECEPTACLES
CAUTION
Receptacles may be marked with rating value greater than generator output capacity.
•NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.
•DO NOT overload the generator. See “Don’t Overload Generator”.
12 Volt DC, 10 Amp Receptacle
This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cables provided (Figure 11).
Figure 11 — 12 Volt DC, 10 Amp Receptacle
This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See the section “Charging a Battery” (page 11) before attempting to recharge a battery.
120 Volt AC, 20 Amp, Duplex Receptacle
Each receptacle (Figure 12) is protected against overload by a 20 Amp
Figure 12 — 120 Volt AC, 20 Amp, Duplex Receptacle
Use each receptacle to operate 120 Volt AC,
120 Volt AC, 30 Amp Locking Receptacle
Use a NEMA
14