7500EXL Extended Life Generator
KNOW YOUR GENERATOR
Read this Operator’s Manual and safety rules before operating your generator.
Compare this illustration with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
Electric Start Button | Recoil Starter |
Oil Fill Cap
Circuit Breakers (AC)
Fuel Tank
12 Volt DC
Receptacle
Idle Control Switch | Choke Lever | |
120/240 Volt AC, | Run/Stop Switch | |
| ||
30 Amp Locking | Air Cleaner | |
Receptacle | ||
| ||
120 Volt AC, 30 Amp | Spark Arrester Muffler | |
| ||
Locking Receptacle | 120/240 Volt AC, | |
| ||
120 Volt AC, 20 Amp | 50 Amp Receptacle | |
Grounding Fastener | ||
Duplex Receptacle |
12 Volt DC Receptacle — Use this receptacle with battery charge cables to charge a 12 Volt battery.
120 Volt AC, 20 Amp Duplex Receptacle — May be used to supply electrical power for the operation of
120 Volt AC, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of
120and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 50 Amp Receptacle — May be used to supply electrical power for the operation of 240 Volt AC, 50 Amp, single phase, 60 Hz electrical loads.
Air Cleaner — Protects engine by filtering dust and debris out of intake air.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Each receptacle is provided with a "push to reset" circuit breaker to protect the generator against electrical overload.
Fuel Tank — Capacity of seven (7) U.S. gallons. Electric Start Switch — Press to start the engine.
Grounding Fastener — Consult your local agency having jurisdiction for grounding requirements in your area.
Idle Control Switch — The idle control runs the engine at normal (high) speeds when there is a load present and runs the engine at idle (low) speeds when a load is not present.
Oil Fill Cap — Add oil to engine here.
Recoil Starter — Used to start the engine manually.
Run/Stop Switch — Must be in “Run” position to start engine. Set to “Stop” to stop a running engine.
Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.
5