7500EXL Extended Life Generator

SPECIFICATIONS

Starting Wattage

.13,500 watts

Wattage

. .7,500 watts

AC Load Current:

 

At 120 Volts

. . .62.5 Amps

At 240 Volts

. . .31.2 Amps

Phase

. . . . .1–phase

Rated Frequency

. . . .60 Hertz

Fuel Tank Capacity

7 U.S. gallons

Shipping Weight

. . . . .240 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: Should you have questions about replacing components on your Generac Portable Products generator, please call 1-800-270-1408for assistance.

Engine Maintenance

See engine operator’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the battery. Keep the battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.

To Clean the Generator

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

17

Page 17
Image 17
Generac 101 9-3 operating instructions Specifications, General Maintenance Recommendations

101 9-3 specifications

The Generac 101 9-3 is a cutting-edge power generation solution designed to meet the diverse needs of both residential and commercial users. Renowned for its robust construction and innovative technologies, this unit stands out in the competitive market of backup generators.

At the heart of the Generac 101 9-3 is its powerful engine, capable of delivering reliable performance in any situation. This generator boasts a high-output capacity, ensuring that it can handle multiple appliances simultaneously during outages. It is particularly well-suited for larger homes and businesses that depend on a steady power supply for critical operations.

One of the main features of the Generac 101 9-3 is its automatic transfer switch (ATS). This technology allows the generator to detect power outages and switch on automatically, ensuring minimal disruption. The ATS guarantees that the transition from grid power to generator power is seamless and instantaneous, providing peace of mind for users.

The unit also showcases a user-friendly control panel with intuitive interfaces, making it easy to monitor performance and adjust settings. Generac has integrated advanced monitoring capabilities, allowing users to track fuel levels, power output, and maintenance schedules. This feature enhances the convenience of ownership and prolongs the lifespan of the generator.

Another remarkable characteristic of the Generac 101 9-3 is its emissions control technology. Designed to meet stringent environmental regulations, this generator operates efficiently while minimizing its carbon footprint. The low-emission engine is a testament to Generac’s commitment to sustainable energy solutions.

In terms of durability, the Generac 101 9-3 is built to withstand harsh weather conditions. Housed in a weatherproof enclosure, it is protected from rain, snow, and extreme temperatures, ensuring reliability in any climate. Its heavy-duty construction provides the longevity needed for prolonged use, making it a worthwhile investment.

Additionally, the Generac 101 9-3 is designed with serviceability in mind. It comes equipped with easily accessible components, simplifying maintenance and repair tasks. This thoughtful design feature helps reduce downtime and keeps the generator running at peak performance.

In conclusion, the Generac 101 9-3 is a high-performance generator that combines power, efficiency, and durability. Its automatic transfer switch, advanced monitoring, emissions control technology, and user-friendly design make it an excellent choice for anyone in need of a reliable power backup solution. Whether for home or business use, the Generac 101 9-3 stands ready to deliver dependable energy when it’s needed most.