Generac Power Systems 005221-0 owner manual  Electrical Hazards 

Models: 005221-0

1 60
Download 60 pages 31.75 Kb
Page 4
Image 4

Standby Generator Sets

Important Safety Instructions

Before performing any maintenance on the gen- erator, disconnect its battery cables to prevent accidental start-up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last.

Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating con- ditions from leaking exhaust gases, fuel leakage, oil leakage, etc.

ELECTRICAL HAZARDS

All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as well as the standby generator. Avoid contact with bare wires, terminals, connections, etc., on the generator as well as the transfer switch, if applicable. Ensure all appropriate covers, guards and barriers are in place before operating the gen- erator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

If personnel must stand on metal or concrete while installing, operating, servicing, adjusting or repair- ing this equipment, place insulative mats over a dry wooden platform. Work on the equipment only while standing on such insulative mats.

The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground. This grounding will help prevent dangerous electrical shock that might be caused by a ground fault condition in the generator set or by static electricity. Never disconnect the ground wire.

Wire gauge sizes of electrical wiring, cables and cord sets must be adequate to handle the maxi- mum electrical current (ampacity) to which they will be subjected.

Before installing or servicing this (and related) equipment, make sure that all power voltage supplies are positively turned off at their source. Failure to do so will result in hazardous and pos- sibly fatal electrical shock.

Connecting this unit to an electrical system nor- mally supplied by an electric utility shall be by means of a transfer switch so as to isolate the generator electric system from the electric utility distribution system when the generator is operat- ing. Failure to isolate the two electric system power sources from each other by such means will result in damage to the generator and may also result in injury or death to utility power workers due to backfeed of electrical energy.

Generators installed with an automatic transfer switch will crank and start automatically when normal (utility) source voltage is removed or is below an acceptable preset level. To prevent such automatic start-up and possible injury to person- nel, disable the generator’s automatic start circuit (battery cables, etc.) before working on or around the unit. Then, place a “Do Not Operate” tag on the generator control panel and on the transfer switch.

In case of accident caused by electric shock, imme- diately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting imple- ment, such as a dry rope or board, to free the vic- tim from the live conductor. If the victim is uncon- scious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equip- ment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving com- ponents causing injury.

FIRE HAZARDS

Keep a fire extinguisher near the generator at all times. Do NOT use any carbon tetra-chloride type extinguisher. Its fumes are toxic, and the liquid can deteriorate wiring insulation. Keep the extin- guisher properly charged and be familiar with its use. If there are any questions pertaining to fire extinguishers, consult the local fire department.

EXPLOSION HAZARDS

Properly ventilate any room or building housing the generator to prevent build-up of explosive gas.

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no com- bustible materials are left in the generator com- partment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surround- ing the generator clean and free from debris.

These generator sets may operate using one of several types of fuels. All fuel types are potentially FLAMMABLE and/or EXPLOSIVE and should be handled with care. Comply with all laws regulat- ing the storage and handling of fuels. Inspect the unit’s fuel system frequently and correct any leaks immediately. Fuel supply lines must be prop- erly installed, purged and leak tested according to applicable fuel-gas codes before placing this equip- ment into service.

Diesel fuels are highly FLAMMABLE. Gaseous fluids such as natural gas and liquid propane (LP) gas are extremely EXPLOSIVE. Natural gas is lighter than air, and LP gas is heavier than air; install leak detectors accordingly.

08/05

0 .Rev 001 Safety

1-2

Page 4
Image 4
Generac Power Systems 005221-0 owner manual  Electrical Hazards 

005221-0 specifications

Generac Power Systems 005221-0 is a highly reliable portable generator that stands out in the market for its efficiency and advanced features. Designed for both home and recreational use, this generator delivers power when it's needed most, ensuring that users can stay connected and maintain their activities during power outages or job sites without electricity.

One of the main features of the Generac 005221-0 is its robust engine design. It is powered by a reliable OHV (Overhead Valve) engine that offers a consistent power output while maintaining fuel efficiency. This design ensures that the generator can run for extended periods, making it perfect for emergency situations or outdoor events.

The generator boasts a versatile power output, with a maximum capacity of 3,500 running watts and 4,500 starting watts. This level of output allows it to handle essential appliances like refrigerators, lights, and sump pumps, as well as power tools and other higher-demand equipment. The inclusion of multiple outlets, including both 120V and 30A twist-lock outlets, provides flexibility in power distribution, catering to different user needs.

One notable technology incorporated in the Generac 005221-0 is the PowerRush Technology, which offers an extra boost of power for starting larger appliances. This means that users can simultaneously power multiple devices without experiencing any performance dips. Furthermore, the generator is equipped with features that enhance user convenience, including an easy-to-read LED dashboard that displays key information such as power output and oil levels.

Durability and portability are other key characteristics of this generator. It features a compact and lightweight design combined with a sturdy frame and rubberized handle for easy transport. The never-flat wheels ensure that it can be moved easily across various terrains, making it suitable for job sites, camping trips, and other outdoor uses.

In terms of safety, the Generac 005221-0 is designed with an integrated circuit breaker to prevent overloads, as well as a low-oil shutdown feature that stops the engine when oil levels are critically low. This ensures that the generator operates safely and extends its lifespan.

Overall, the Generac Power Systems 005221-0 is an excellent choice for those in need of a dependable, efficient, and versatile portable generator. Its combination of innovative technology, robust features, and user-friendly design makes it a valuable asset for any home or outdoor enthusiast.