Standby Generator Sets

Troubleshooting

TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

CORRECTION

Engine won’t crank.

1.

15 amp fuse blown.

1.

Replace fuse.

 

2.

Loose or corroded or defective

2.

Tighten, clean or replace

 

 

battery cables.

 

battery cables as necessary.

 

3.

Defective starter contactor.

3.

Replace contactor.*

 

4.

Defective starter motor.

4.

Replace starter motor.*

 

5.

Dead or Defective Battery.

5.

Remove, change or replace battery.

 

6.

5 amp fuse blown.

6.

Replace fuse.*

 

 

 

 

 

Engine cranks but won't start

1.

Out of fuel.

1.

Replenish fuel.

 

2.

Fuel solenoid (FS) is defective

2.

Replace solenoid.*

 

3.

Open Wire #14A from Engine Control

3.

Reconnect wire.

 

 

circuit board.

 

 

 

4.

Spark plugs defective.

4.

Clean, regap or replace plugs.

 

5.

Door on tank not closed.

5.

Close door on tank.

 

 

 

 

 

Engine starts hard, runs rough.

1.

Flame arrestor (air cleaner) plugged or

1.

Clean or replace as needed.

 

 

damaged.

 

 

 

2.

Plugged fuel line.

2.

Unclog fuel line.

 

3.

Defective spark plugs.

3.

Clean, regap or replace plugs.

 

4.

Fuel pressure incorrect.

4.

Confirm fuel pressure to regulator is as

 

 

 

 

recommended in SPECIFICATIONS.

 

 

 

 

 

Engine starts then shuts down.

1.

Engine oil level is low.

1.

Check oil and add oil as needed.

 

2.

Engine is overheated.

2.

Check cooling system for leaks.

 

3.

Defective Low Oil Pressure Switch

3.

Replace switch.*

 

4.

Defective Coolant Temperature Switch

4.

Replace switch.*

 

5.

Defective Control Module circuit board.

5.

Replace board.*

 

6.

Coolant Level is Low.

6.

Repair leak - Add coolant.

 

7.

Defective Low Coolant Level Switch

7.

Replace Switch.*

 

 

 

 

 

AUTO/OFF/MANUAL Switch at OFF,

1.

Defective AUTO/OFF/MANUAL switch

1.

Replace switch.*

engine continues to run

2.

Open/disconnected wire #15A between

2.

Reconnect/close wire.

 

 

AUTO/OFF/MANUAL switch and Control

 

 

 

 

Module circuit board.

 

 

 

3.

Defective Control Module circuit board

3.

Replace board.*

 

 

 

 

 

No AC output from generator.

1.

Check main line circuit breaker.

1.

Reset to ON or CLOSED.

 

2.

Check circuit breaker & fuses.

2.

Reset and replace, if necessary.

 

3.

Transfer switch set to NORMAL position

3.

Set to GENERATOR position.

 

4.

Generator internal failure.

4.

*

 

5.

Thermal circuit breaker open.

5.

Auto-reset - Wait 5 min. and

 

 

 

 

attempt restart.

*Contact the nearest Authorized Dealer for assistance.

12-1

08/05

0 .Rev Trblsht001

Page 24
Image 24
Generac Power Systems 005223-0 owner manual Troubleshooting Guide, Problem Cause Correction

005223-0 specifications

Generac Power Systems has established itself as a prominent name in the field of power generation, and the Generac 005223-0 model exemplifies the company's commitment to innovative technology and reliable performance. This portable generator is designed for various applications, from home backup power to outdoor events, ensuring users have access to electricity when they need it the most.

One of the standout features of the Generac 005223-0 is its impressive power output. With a capacity that typically exceeds 3000 watts, this generator can handle essential home appliances, tools, and more, providing peace of mind during power outages or when electricity is required away from a stationary power source. The generator is equipped with a powerful, efficient engine that optimizes fuel consumption while delivering maximum performance.

In addition to its robust power capabilities, the 005223-0 incorporates Generac’s patented PowerRush technology, which enhances the starting capacity, allowing users to start larger loads such as air conditioners or power tools without any issue. This technology significantly increases the generator’s output upon startup, making it an excellent choice for users needing to power multiple devices simultaneously.

Safety is a primary concern for Generac, and the 005223-0 exemplifies this commitment through its built-in protection features. The generator includes low-oil shutdown, which automatically turns off the engine when the oil level drops too low, preventing damage and ensuring longevity. Furthermore, the unit is designed with a sturdy frame to withstand various conditions, making it suitable for both residential and commercial use.

Another notable characteristic of the 005223-0 is its user-friendly interface. The generator's control panel is intuitively laid out, providing easy access to power settings, fuel gauge, and various output options. This makes operation straightforward, even for those who are not well-versed in generator technology.

Lastly, portability is a key feature of the Generac 005223-0, as it is designed with rugged wheels and a lightweight structure, enabling easy transportation to different locations. Whether it’s for outdoor gatherings, camping trips, or emergency backup, this generator is exceptional in versatility and reliability. With the 005223-0, users can expect a seamless power solution backed by Generac’s reputation for quality and service.