Generac Power Systems 04758-0 Service Schedule, ATTENTION It is recommended that all service work

Models: 04760-0 04759-0 04758-0

1 56
Download 56 pages 11.1 Kb
Page 24
Image 24
4.13 SERVICE SCHEDULE

Section 4 — Maintenance

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

4.13 SERVICE SCHEDULE

ATTENTION: It is recommended that all service work

be performed by your nearest Generac Authorized Dealer.

 

SYSTEM/COMPONENT

 

 

PROCEDURE

 

FREQUENCY

 

 

X = Action

Inspect

 

Change

 

Clean

W = Weekly

 

 

R = Replace as Necessary

 

 

 

 

 

M = Monthly

 

 

* = Notify Dealer

 

 

 

 

 

Y = Yearly

 

 

if Repair is Needed.

 

 

 

 

 

 

 

 

FUEL

 

 

 

 

 

 

 

 

Fuel lines and connections*

X

 

 

 

 

M

 

 

LUBRICATION

 

 

 

 

 

 

 

 

Oil level

X

 

 

 

 

M

 

 

Oil

 

 

X

 

 

AFTER BREAK-IN,

 

 

 

 

 

 

 

 

 

AND Y

 

 

Oil filter

 

 

X

 

 

AFTER BREAK-IN,

 

 

 

 

 

 

 

 

 

AND Y

 

 

COOLING

 

 

 

 

 

 

 

 

Enclosure louvers

X

 

 

 

X

W

 

 

BATTERY

 

 

 

 

 

 

 

 

Remove corrosion,

X

 

 

 

X

M

 

 

ensure dryness

 

 

 

 

 

 

 

 

Clean and tighten

X

 

 

 

X

M

 

 

battery terminals

 

 

 

 

 

 

 

 

Check charge state

X

 

R

 

 

EVERY 6 M

 

 

Electrolyte level

X

 

R

 

 

EVERY 6 M

 

 

(unsealed batteries only)*

 

 

 

 

 

 

 

 

ENGINE AND MOUNTING

 

 

 

 

 

 

 

 

Air cleaner

 

X

 

R

 

 

Y

 

 

Spark plug(s)

 

X

 

R

 

 

Y

 

 

GENERAL CONDITION

 

 

 

 

 

 

 

 

Vibration, Noise, Leakage,

X

 

 

 

 

M

 

 

Temperature*

 

 

 

 

 

 

 

 

COMPLETE TUNE-UP*

TO BE COMPLETED BY A GENERAC

Y

 

 

 

 

 

AUTHORIZED DEALER

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Page 24
Image 24
Generac Power Systems 04758-0, 04759-0, 04760-0 Service Schedule, ATTENTION It is recommended that all service work