Generac Power Systems QT018 manual Operating Data

Models: QT018

1 4
Download 4 pages 63.58 Kb
Page 3
Image 3
OPERATING DATA

QT018

OPERATING DATA

 

 

 

QT018

 

KW RATING

 

 

18

 

 

 

 

 

 

ENGINE SIZE

 

 

1.6 Liter 4 cyl. inline

 

 

 

 

 

 

GENERATOR OUTPUT VOLTAGE/KW - 60Hz

 

KW

AMP

CB Size

120/240V, 1-phase, 1.0 pf

 

18

75

 

120/208V, 3-phase, 0.8 pf

 

18

62

70

 

 

 

 

 

GENERATOR LOCKED ROTOR KVA

 

 

 

 

AVAILABLE @ VOLTAGE DIP OF 35%

 

 

 

 

Single phase or 208 3-phase

 

 

34

 

 

 

 

ENGINE FUEL CONSUMPTION (Natural Gas) (Propane)

Natural Gas

Propane

 

 

(ft3/hr.)

(gal/hr.)

cu ft/hr

Exercise cycle

 

48

0.52

19

25% of rated load

 

109

1.19

43

50% of rated load

 

165

1.80

65

75% of rated load

 

220

2.41

87

100% of rated load

 

278

3.04

110

 

 

 

 

 

ENGINE COOLING

 

 

 

 

Air flow (inlet air including alternator and combustion air)

ft3/min.

 

1,600

 

System coolant capacity

US gal.

 

2.0

 

Heat rejection to coolant

BTU/hr.

 

96,000

 

Max. operating air temp. on radiator

°C (°F)

 

60 (150)

 

Max. ambient temperature

°C (°F)

 

50 (140)

 

 

 

 

 

 

COMBUSTION AIR REQUIREMENTS

 

 

 

 

Flow at rated power 60 Hz

cfm

 

48

 

 

 

 

 

 

SOUND EMISSIONS IN DBA

 

 

 

 

Exercising at 7 meters

 

 

58

 

Full load at 7 meters

 

 

67

 

 

 

 

 

 

EXHAUST

 

 

 

 

Exhaust flow at rated output 60 Hz

cfm

 

125

 

Exhaust temp. at muffler outlet

°F

 

890

 

 

 

 

 

 

ENGINE PARAMETERS

 

 

 

 

Rated synchronous RPM

60 Hz

 

1800

 

HP at rated KW

60 Hz

 

28

 

 

 

 

 

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

 

 

 

Temperature Deration

 

 

 

 

3% for every 10 °C above - °C

 

25

 

1.65% for every 10 °F above - °F

 

77

 

Altitude Deration

 

 

 

 

1% for every 100 m above - m

 

183

 

3% for every 1000 ft. above - ft.

 

600

 

 

 

 

 

 

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.

KW rating is based on LPG Fuel and may derate with natural gas.