W1761/W1762 12" Table Saw with Riving Knife

ELECTRICAL

ELECTRICAL

The machine must be properly set up before it is safe to operate. DO NOT connect this machine to the power source until instructed to do so in the "Test Run" portion of this manual.

W1761 220V Single-Phase

Operation

The Model W1761 is wired for 220V single-phase opera- tion. We recommend connecting this machine to a dedi- cated circuit with a verified ground, using the circuit size given below. Never replace a circuit breaker with one of higher amperage without consulting a qualified electrician to ensure compliance with wiring codes. This machine must be connected to a grounded circuit!

A plug is not supplied with this machine. See below for the recommended plug type for this machine.

If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire or circuit overload hazard— consult a qualified electrician to reduce this risk.

Extension Cords

We do not recommend using an extension cord; however, if you have no alternative, use the following guidelines:

Use a cord rated for Standard Service (S).

Do not use an extension cord longer than 50 feet.

Ensure that the cord has a ground wire and pin.

Use the gauge size listed below as a minimum.

W1761 Electrical

Specifications

L6-30 P

L6-30 R

Figure 7. L6-30 plug and receptacle.

DO NOT work on your electrical system if you are unsure about electrical codes and wiring! Seek assistance from a qualified electrician. Ignoring this warning can cause electrocution, fire, or machine damage.

Operating Voltage

Amp Draw

Min. Circuit Size

Recommended Plug

Extension Cord

220V Operation

23 Amps

30A

NEMA L6-30 (not

10 Gauge, 3 Wire,

 

 

 

incl.) (See Figure 7)

250V

-12-

Page 26
Image 26
Woodstock W1762 owner manual W1761 220V Single-Phase Operation, Extension Cords, W1761 Electrical Specifications