Divar XF | Hardware setup en 31 |
|
|
Specifications
Output impedence: 128 ohm
Overvoltage protection: ±40 V maximum
Differential voltage amplitude: 1 V minimum, 2 V maximum with a characteristic load of 220 ohms connected across the differential output
Cable length: 1.5 Kilometers maximum
Recommended cable: Belden 8760
Cable diameter: AWG
Number of loads per output: 4 maximum
81
159
BIPHASE
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD |
| ||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| + |
| |||||
|
|
|
|
|
| CTRL 1 |
| |||||
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD |
| ||||
|
|
|
|
|
| + |
| |||||
|
|
|
|
|
| CTRL 2 |
| |||||
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD |
| ||||
|
|
|
|
|
| + |
| |||||
|
|
|
|
|
| CTRL 3 |
| |||||
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD |
| ||||
|
|
|
|
|
| + |
| |||||
|
|
|
|
|
| CTRL 4 |
| |||||
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD |
| ||||
|
|
|
|
|
| + |
| |||||
|
|
|
|
|
| CTRL 5 |
| |||||
|
|
|
|
|
| - |
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD |
| ||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
Figure 4.16 Biphase port connector and connection board | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Signal name | Pin number | Description | ||||||||||
Code 1 - | 1 |
|
|
|
| Biphase control ch. 1 (minus) | ||||||
Code 1 + | 2 |
|
|
|
| Biphase control ch. 1 (plus) | ||||||
Shield | 3 |
|
|
|
| System ground/cable shield | ||||||
Code 2 - | 4 |
|
|
|
| Biphase control ch. 2 (minus) | ||||||
Code 2 + | 5 |
|
|
|
| Biphase control ch. 2 (plus) | ||||||
Shield | 6 |
|
|
|
| System ground/cable shield | ||||||
Code 3 - | 7 |
|
|
|
| Biphase control ch. 3 (minus) | ||||||
Code 3 + | 8 |
|
|
|
| Biphase control ch. 3 (plus) | ||||||
Shield | 9 |
|
|
|
| System ground/cable shield | ||||||
Code 4 - | 10 |
|
|
|
| Biphase control ch. 4 (minus) | ||||||
Code 4 + | 11 |
|
|
|
| Biphase control ch. 4 (plus) | ||||||
Shield | 12 |
|
|
|
| System ground/cable shield | ||||||
Code 5 - | 13 |
|
|
|
| Biphase control ch. 5 (minus) | ||||||
Code 5 + | 14 |
|
|
|
| Biphase control ch. 5 (plus) | ||||||
Shield | 15 |
|
|
|
| System ground/cable shield |
Table 4.6 Control port -
Bosch Security Systems | Installation manual | F.01U.135.429 2.5 2009.08 |