4.15

34 en Hardware setupDivar XF

4.15

Malfunction relay

 

The malfunction relay will be activated upon system failure. Connect using the supplied screw

 

terminal adapter. The recommended cable diameter is AWG 28-16 (0.08-1.5 mm2).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- + G

 

 

 

 

 

 

 

 

 

RS

 

 

 

 

 

 

 

 

 

 

 

 

485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

N0 C NC

 

Figure 4.19 Malfunction relay output

4.16

Power supply

Power is supplied to the unit via the IEC-style socket. For security reasons, the unit has no on/ off switch. This means that the unit is always powered as long as the power cable from the unit is connected to a live power socket.

Specifications:

Input Voltage: 100 - 240 VAC ±10%

Current: 0.7A - 0.3 A

Input Frequency: 50/60 Hz

AC

Figure 4.20 Power supply socket

Signal name

Pin

Description

LIVE

Top

AC live

NEUTRAL

Bottom

AC neutral

PE

Middle

Protective Earth

Table 4.9 Power supply socket

4.17Maintenance

Maintenance of this unit is limited to external cleaning and inspection. Refer all servicing to qualified service personnel.

DANGER!

Electrical voltage. Risk of electric shock.

Do not open the top cover or attempt to service the unit. No user serviceable parts inside. Refer all servicing to qualified service personnel. Opening the top cover will void the warranty!