Bosch Appliances XF 5.9.2Logbook, Sensors, Sensor name, Lower limit, Upper limit, Voltage level

Models: XF

1 88
Download 88 pages 39.1 Kb
Page 49
Image 49
Sensors

Divar XF

Operating instructions en 49

 

 

Alarm recording at input - displays which inputs are in alarm recording mode Motion recording at input - displays which inputs are in motion recording mode

Current recording status - displays video and audio recording status and mode for each input

Sensors

Displays actual temperature and voltage sensor values. If temperature levels are outside of the normal range, the displayed values are yellow. If this occurs, check that the ambient temperature is within the recommended specifications and that there is proper air ventilation. If the temperature reaches a critical level, the unit automatically shuts down. To restart the unit, disconnect the power cord, wait for at least 30 seconds, and then reconnect the power cord.

Sensor name

Lower limit

Upper limit

 

 

 

Processor

5 °C / 41 °F

100 °C / 212 °F

 

 

 

Air inlet

5 °C / 41 °F

45 °C / 113 °F

 

 

 

Air outlet

5 °C / 41 °F

55 °C / 131 °F

 

 

 

Hard disk #1

5 °C / 41 °F

55 °C / 131 °F

 

 

 

Hard disk #2

5 °C / 41 °F

55 °C / 131 °F

 

 

 

Hard disk #3

5 °C / 41 °F

55 °C / 131 °F

 

 

 

Hard disk #4

5 °C / 41 °F

55 °C / 131 °F

 

 

 

Table 5.1 Temperature sensors

 

 

Voltage level

Lower limit

Upper limit

 

 

 

12 Volt

10.8 V

13.2 V

 

 

 

5 Volt

4.7 V

5.3 V

 

 

 

3.3 Volt

3.1 V

3.5 V

 

 

 

Table 5.2 Power supply levels

5.9.2Logbook

The logbook menu is used to display a filtered history of system events.

Logbook filter

Set various filter criteria to search in a specified time period for various system events.

Bosch Security Systems

Installation manual

F.01U.135.429 2.5 2009.08

Page 49
Image 49
Bosch Appliances XF 5.9.2Logbook, Sensors, Sensor name, Lower limit, Upper limit, Voltage level, Logbook filter