HP DL380 Generation 7 (G7) manual Power Specifications

Models: DL380 Generation 7 (G7)

1 62
Download 62 pages 16.09 Kb
Page 54
Image 54

QuickSpecs

HP ProLiant DL380 Generation 7 (G7)

Power Specifications

HP 460W Common Slot Gold Hot Plug Power Supply Kit

Part Number

503296-B21

 

 

 

 

 

 

Input Voltage Range ( V rms )

100 to 240

 

 

 

 

 

 

Frequency Range (Nominal) ( Hz )

50/60

 

 

 

 

 

 

 

Nominal Input Voltage ( Vrms )

100

 

120

200

208

220

230

240

Maximum Rated Output Wattage Rating

460

 

460

460

460

460

460

460

Nominal Input Current ( A rms )

5.5

 

4.5

2.6

2.5

2.4

2.3

2.2

Maximum Rated Input Wattage Rating ( Watts )

526

 

520

505

505

503

503

503

Maximum Rated VA ( Volt-Amp )

548

 

542

527

527

524

524

524

Efficiency ( % )

87.5

 

88.5

91

91

91.5

91.5

91.5

Power Factor

 

 

 

 

0.97

 

 

 

Leakage Current ( mA )

0.42

 

0.50

0.83

0.87

0.92

0.96

1.00

Maximum Inrush Current ( A peak )

 

 

 

 

30

 

 

 

Maximum Inrush Current duration ( mS )

 

 

 

 

20

 

 

 

Maximum British Thermal Unit Rating ( BTU-Hr )

1794

 

1773

1725

1725

1715

1715

1715

 

 

 

 

 

 

 

HP 460W Common Slot Platinum Hot Plug Power Supply Kit

 

 

 

 

 

 

Part Number

593188-B21

 

 

 

 

 

 

Input Voltage Range ( V rms )

100 to 240

 

 

 

 

 

 

Frequency Range (Nominal) ( Hz )

50/60

 

 

 

 

 

 

 

Nominal Input Voltage ( Vrms )

100

 

120

200

208

220

230

240

 

 

 

 

 

 

 

 

 

Maximum Rated Output Wattage Rating

460

 

460

460

460

460

460

460

Nominal Input Current ( A rms )

5.3

 

4.3

2.5

2.4

2.3

2.2

2.1

Maximum Rated Input Wattage Rating ( Watts )

512

 

505

493

493

492

492

491

Maximum Rated VA ( Volt-Amp )

526

 

518

506

506

505

505

504

Efficiency ( % )

89.8

 

91.2

93.2

93.3

93.5

93.6

93.6

Power Factor

 

 

 

 

0.985

 

 

 

Leakage Current ( mA )

0.42

 

0.50

0.83

0.87

0.92

0.96

1.00

Maximum Inrush Current ( A peak )

 

 

 

 

30

 

 

 

Maximum Inrush Current duration ( mS )

 

 

 

 

20

 

 

 

Maximum British Thermal Unit Rating ( BTU-Hr )

1747

 

1722

1683

1682

1679

1678

1677