QuickSpecs
HP ProLiant DL380 Generation 7 (G7)
Technical Specifications
|
| 750 W (at 100 to 120 VAC), | ||
|
| 750 W (at 200 to 240 VAC) | ||
|
| For 460 W Power Supply: |
|
|
|
| 460 W (at 100 to 120 VAC), | ||
|
| 460 W (at 200 to 240 VAC) | ||
| Maximum Peak Power | For 1200 W Power Supply: | ||
|
| 800 W (at 100 VAC), |
|
|
|
| 900 W (at 120 VAC), |
|
|
|
| 1200 W (at 200 to 240 VAC) | ||
|
| For 750 W Power Supply: |
|
|
|
| 750 W (at 100 to 120 VAC), | ||
|
| 750 W (at 200 to 240 VAC) | ||
|
| For 460 W Power Supply: |
|
|
|
| 460 W (at 100 to 120 VAC), | ||
|
| 460 W (at 200 to 240 VAC) | ||
System Inlet | Operating | 10° to 35°C (50° to 95°F) at sea level with an | ||
Temperature |
| altitude derating of 1.0°C per every 305 m (1.8°F | ||
|
| per every 1000 ft) above sea level to a maximum | ||
|
| of 3050 m (10,000 ft), no direct sustained | ||
|
| sunlight. Maximum rate of change is 10°C/hr | ||
|
| (18°F/hr). The upper limit may be limited by the | ||
|
| type and number of options installed. | ||
|
| System performance may be reduced if operating | ||
|
| with a fan fault or above 30°C (86°F). | ||
| ||||
|
| change is 20°C/hr (36°F/hr). | ||
Relative Humidity | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) | ||
| maximum wet bulb temperature, non- | |||
|
| condensing. |
|
|
| 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) | |||
|
| maximum wet bulb temperature, non- | ||
|
| condensing. |
|
|
Altitude | Operating | 3050 m (10,000 ft). This value may be limited by | ||
|
| the type and number of options installed. | ||
|
| Maximum allowable altitude change rate is 457 | ||
|
| m/min (1500 ft/min). |
|
|
| 9144 m (30,000 ft). Maximum allowable altitude | |||
|
| change rate is 457 m/min (1500 ft/min). | ||
Acoustic Noise | Listed are the declared | |||
| average bystander position | |||
| the product is operating in a 23°C ambient environment. Noise emissions were | |||
| measured in accordance with ISO 7779 (ECMA 74) and declared in accordance | |||
| with ISO 9296 (ECMA 109). |
|
|
|
| NOTE: The Listed sound levels apply to standard shipping configurations. | |||
| Additional options may result in increased sound levels. | |||
| Idle | 1P SKU | 2P SKU | |
| LWAd | 4.1 B | 4.7 B | |
| LpAm | 22 dBA | 28 dBA | |
|
|
| ||
DA - 13595 Worldwide — Version 65 — March 25, 2013 | Page 58 |