QuickSpecs

HP ProLiant DL380 Generation 7 (G7)

Power Specifications

HP 750W Common Slot Gold Hot Plug Power Supply Kit

Part Number

512327-B21

 

 

 

 

 

 

Input Voltage Range ( V rms )

100 to 240

 

 

 

 

 

 

Frequency Range (Nominal) ( Hz )

50/60

 

 

 

 

 

 

 

Nominal Input Voltage ( Vrms )

100

 

120

200

208

220

230

240

Maximum Rated Output Wattage Rating

750

 

750

750

750

750

750

750

Nominal Input Current ( A rms )

8.9

 

7.4

4.3

4.1

3.9

3.7

3.6

Maximum Rated Input Wattage Rating ( Watts )

857

 

847

824

824

820

820

820

Maximum Rated VA ( Volt-Amp )

894

 

884

859

854

854

854

 

Efficiency ( % )

87.5

 

88.5

91

91

91.5

91.5

91.5

Power Factor

 

 

 

 

0.97

 

 

 

Leakage Current ( mA )

0.42

 

0.50

0.83

0.87

0.92

0.96

1.00

Maximum Inrush Current ( A peak )

 

 

 

 

30

 

 

 

Maximum Inrush Current duration ( mS )

 

 

 

 

20

 

 

 

Maximum British Thermal Unit Rating ( BTU-Hr )

2925

 

2892

2812

2812

2797

2797

2797

 

 

 

 

 

 

 

HP 750W Common Slot Platinum Hot Plug Power Supply Kit

 

 

 

 

 

 

Part Number

593831-B21

 

 

 

 

 

 

Input Voltage Range ( V rms )

100 to 240

 

 

 

 

 

 

Frequency Range (Nominal) ( Hz )

50/60

 

 

 

 

 

 

 

Nominal Input Voltage ( Vrms )

100

 

120

200

208

220

230

240

Maximum Rated Output Wattage Rating

750

 

750

750

750

750

750

750

Nominal Input Current ( A rms )

8.6

 

7.1

4.2

4.0

3.8

3.6

3.4

Maximum Rated Input Wattage Rating ( Watts )

841

 

828

809

808

807

806

805

Maximum Rated VA ( Volt-Amp )

863

 

850

830

829

828

827

826

Efficiency ( % )

89.2

 

90.6

92.7

92.8

93

93.1

93.2

Power Factor

 

 

 

 

0.985

 

 

 

Leakage Current ( mA )

0.42

 

0.50

0.83

0.87

0.92

0.96

1.00

Maximum Inrush Current ( A peak )

 

 

 

 

30

 

 

 

Maximum Inrush Current duration ( mS )

 

 

 

 

20

 

 

 

Maximum British Thermal Unit Rating ( BTU-Hr )

2868

 

2825

2761

2757

2753

2749

2747